5.1 Setting the DIP Switches
Layout of
SWENC |
|
| SWR |
TM1 | TM2 |
Chapter 5 SETTING
How to Set Switches SWENC and SWR [ON/OFF]
| O |
|
| 1 |
|
|
|
|
| ||
|
|
|
| ||
| F |
|
| 2 |
|
| F |
|
|
|
Slide to the (OFF) marked side of the switch to turn it off and the opposite side to turn it on.
Figure 5-1 Switch arrangement figure
5.2 Switch Initial Settings
Setting | Switch |
| Contents |
|
|
|
|
| ||
item | No. |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
|
| ON | Detection of disconnected | A | or | B | signal | or | ||
| 1 |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
SWENC | OFF | Detection of disconnected | A | or | B | signal | or | |||
| ||||||||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
| 2 | ON | Detection of disconnected Z signal |
| ||||||
| OFF | Detection of disconnected Z signal |
| |||||||
|
|
| ||||||||
|
| ON | Termination resistance is provided between SAP and SAN | |||||||
| 1 | (150 ohms). |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
SWR |
| OFF | No terminal resistance is provided between SAP and SAN. |
| ||||||
2 | ON | Termination resistance is provided between SBP and SBN | ||||||||
| ||||||||||
| (150 ohms). |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
|
| OFF | No terminal resistance is provided between SBP and SBN. |
|
(Note) : Default setting for all the switches is OFF.
16