MANAGER PROGRAMMING (Machine Must Be In READY Mode)
To enter the Manager Programming Mode, you must first enter the Operator Programming Mode by pressing and holding "LX40" on the control panel (this is the HIDDEN key), then pressing WASH. Once you are in the Operator Programming Mode, press SELECT until PROGRAM is lit. Press and hold the HIDDEN key, then press WASH again to enter the Manager Programming Mode.
The possible options to edit are listed in the following table. Use SELECT to move through each parameter. When the parameter you wish to reprogram is displayed, use UP ARROW to change the value. After the correct value is displayed, press SELECT to lock in the displayed value and to move to the next programming option. The programming range of values for each parameter is shown in the table under Programmable Variables and Recommended Settings — Models LX40H & LX40C, page 20.
| PARAMETER | DISPLAY SHOWS | |
| Sump temperature. | PROGRAM, with the display alternating between SUMP |
|
|
| and the programmed temperature. | |
| Booster temperature ("H" model only) | PROGRAM, with the display alternating between BOOST |
|
|
| and the programmed temperature. | |
| °F / °C | PROGRAM, and the °F or °C prompt. |
|
| Detergent pump time. | PROGRAM, DETERGENT, and programmed time. | |
| Rinse agent pump ratio. | PROGRAM, RINSE AGENT and programmed ratio. |
|
| Sanitizer pump ratio ("C" Model only). | PROGRAM, SANITIZER and programmed ratio. | |
| Cycle selection lockout. | PROGRAM and LOCK or UNLK. |
|
| Default cycle selection. (Default means "cycle | PROGRAM, current default cycle indicator, and the | |
| selected upon | DEFLT prompt. |
|
| Automatic delime reminder. | PROGRAM, DELIME and programmed number of cycles. | |
| Detergent prime time. | PROGRAM, PRIME, and DETERGENT lit with the |
|
|
| programmed time displayed. |
|
| Rinse agent prime time. | PROGRAM, PRIME, and RINSE AGENT lit with the | |
|
| programmed time displayed. | |
|
|
| |
| Sanitizer prime time. | PROGRAM, PRIME, and SANITIZER lit with programmed |
|
|
| time displayed. |
|
| Heavy wash cycle - wash time. | PROGRAM, WASH and programmed time. | |
| Heavy wash cycle - rinse time. | PROGRAM, RINSE and programmed time (NORM or |
|
|
| EXTEN). |
|
| Idle shutdown time. | PROGRAM, with display alternating between "SHDN" | |
|
| and the programmed shutdown time in hours. |
To exit the manager programming mode do one of the following:
1.Press OFF (machine shuts down but does not drain).
2.Press SELECT until the display shows READY.
3.Press and hold the HIDDEN key, then press WASH.
– 19 –