Hobart LX18H, LX18C, LX40C, LX30H, LX30C manual Use stranded copper wire only

Models: LX18 LX30C LX30H LX40C LX30 LX18C LX18H

1 28
Download 28 pages 40 Kb
Page 7
Image 7
Use stranded copper wire only.

Refer to the data plate on the front of the machine and the label inside the control drawer at the power connection for proper selection.

Use stranded copper wire only.

1.Remove the cover plate at the upper right in the back of the machine (Fig. 1). A hole for 1" trade size conduit is supplied in the cover plate.

Manual background Cover Plate

PL-40805-1

Screws

PL-40163-1

Fig. 1

Fig. 2

2.Open dishwasher door and remove the 2 screws (Fig. 2) securing the controls drawer. Close the dishwasher door and open the controls drawer fully.

3.Install 1" trade conduit and fitting to the cover plate. A 90° fitting is recommended.

4.Feed wires over top of tank to strain relief(s) at rear of drawer. At least 32" and not more than 36" of the required wire size must extend from the end of the conduit fitting.

5.Reinstall the cover plate (3 screws, Fig. 1).

6.For 8 AWG wire, run no more than 2 wires through any strain relief (two strain reliefs are provided). Make electrical connections per the wiring diagram supplied with the machine, and secure wires to power terminal block and ground.

For 12 or 14 AWG wire, run 3 wires (or 4 wires if required) through the strain relief provided by Hobart. Make electrical connections per the wiring diagram supplied with the machine. Secure wires to the power terminal block and ground. Keep excess wire in the drawer to a minimum.

7.Tighten the set screw on the strain relief(s) until they bottom out (on the shoulder of the body).

8.Close the control drawer and replace the screws.

– 7 –

Page 7
Image 7
Hobart LX18H, LX18C, LX40C, LX30H, LX30C manual Use stranded copper wire only