1.Remove standpipe assemblies from chemical containers and place them as close to the floor as possible. Place a catch pan under them.

2.Cycle the machine four times to clear the lines of chemicals.

3.Remove rack from machine.

4.Add deliming agent (carefully follow supplier's instructions). The sump holds approximately 3 gallons of water.

5.Close door. Press WASH and allow machine to complete the wash/rinse cycle.

6.Press OFF.

7.Inspect the interior of the machine for lime deposits. If necessary, press ON to fill machine and repeat steps 4 through 7.

8.Press ON. Run two cycles to purge the system of deliming agent. Press OFF.

9.Put standpipe assemblies back into the appropriate chemical containers (see page 8).

10.Press ON. Run four cycles to prime the chemical delivery pumps.

11.Press OFF.

CAUTION: Do not allow the deliming agent to remain in the machine longer than recommended by the deliming agent manufacturer.