Hobart HQCF45, ML-124068, HQC90, ML-124066, ML-124067 From the Main Menu, select MORE and HOLD PROD

Models: ML-124067 ML-124066 HQCF45 HQC90 ML-124068

1 32
Download 32 pages 23.37 Kb
Page 17
Image 17
From the Main Menu, select MORE and HOLD PROD.

HOLD PROD — After Chilling or when selected, runs the chiller like a regular refrigerator.

MAIN MENU 08:05:01

Manual backgroundBY TEMP BY PRODManual background

Manual backgroundBY TIME

MORE

MAIN MENU 08:06:01

Manual backgroundHOLD PROD PRINTManual background

Manual backgroundDEFROST SETUPManual background

Manual backgroundBACK

SELECT HOLD MODE: Manual backgroundREFRIGERATOR

Manual backgroundFREEZER Manual backgroundBACK

HOLDING

AIR: 34°F

1

37°F

37°F 3

2

37°F

 

0:00:04

EXIT

From the Main Menu, select MORE and HOLD PROD.

Select REFRIGERATOR or FREEZER mode, if available.

(BACK returns to the Main Menu.)

(Temperatures are indicated for air and probes.)

(Timer indicates the run time.)

(EXIT returns to the Main Menu; however, Hold mode continues until another selection is made.)

NOTE: HOLD mode does not retain temperature vs. time data in memory; printed reports are not available.

NOTE: Freezer Hold mode is only

available on Model HQCF45.

– 17 –

Page 17
Image 17
Hobart HQCF45, ML-124068, HQC90, ML-124066, ML-124067 manual From the Main Menu, select MORE and HOLD PROD