•Access the Sys Par 2 menu as shown on page 21.
SYS PAR 1 | 09:07:31 |
|
|
|
CLOCK TEMPS IN °F |
|
|
| |
PROBES | LOGGING |
|
|
|
SETUP MENU | MORE | SYS PAR 2 | 09:08:41 | |
|
| REMOTE ALARM MODE | ||
|
| ALARMS |
| BUZZER |
|
| BACK | FAC PRESETS |
MODE
MODE PARAMETERS
CHILL FREEZE
SOFT CHILL
BACK
•From Sys Par 2, select MODE.
•From Mode Parameters, select CHILL. (BACK returns to SYS PAR 2.)
CHILL |
|
CHILL MODE EDITOR | |
↓ TARGET | 37 ° F ↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
CHILL MODE EDITOR | |
↓AIR | 10°F↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
CHILL MODE EDITOR | |
↓HOLD | 37°F↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
CHILL MODE EDITOR | |
↓HIGH ALARM | 45°F↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
CHILL MODE EDITOR | |
↓LOW ALARM | 32°F↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
CHILL MODE EDITOR | |
↓CHILL MAX | 40°F↑ |
←BACK | NEXT→ |
CANCEL | ENTER |
NOTE: To extend the Target Temp range for Chill and Soft Chill modes, first change the CHILL MAX value. Then change the Target Temp. The Target Temp range can be extended to as high as 55°F.
•Set the TARGET Temp using the ↓ or ↑ keys.
Range: [33°F to 40°F].
•Select NEXT to move to the next field. (BACK returns to the previous field.)
•Set the AIR Temp using the ↓ or ↑ keys.
Range: [10°F to 40°F].
•Select NEXT to move to the next field.
•Set the HOLD Temp using the ↓ or ↑ keys.
Range: [10°F to 40°F].
•Select NEXT to move to the next field.
•Set the HIGH ALARM Temp using the ↓ or ↑ keys.
Range: [35°F to 60°F].
•Select NEXT to move to the next field.
•Set the LOW ALARM Temp using the ↓ or ↑ keys.
Range:
•Select NEXT to move to the next field.
•Set the CHILL MAX Temp using the ↓ or ↑ keys.
Range: [40°F to 55°F].
(NEXT returns to the TARGET TEMP screen.)
•Select ENTER to keep any changes and return to Mode Parameters.
(CANCEL retains the previous settings and returns to Mode Parameters.)
– 26 –