Hobart ML-124066, ML-124068, HQC90, HQCF45 manual Operation, CONTROLS Fig, Start-Up, Over Temperature

Models: ML-124067 ML-124066 HQCF45 HQC90 ML-124068

1 32
Download 32 pages 23.37 Kb
Page 8
Image 8
OPERATION

OPERATION

CONTROLS (Fig. 4)

MAIN MENU

08:05:01

BY

TEMP

BY PROD

BY

TIME

 

 

 

MORE

Fig. 4

Choose a selection from the menu that appears on the control’s display by pressing the button graphically connected to the display prompt. Four buttons are arranged on the left and four on the right.

For example, to select By Temp, press the second button on the left.

START-UP

SmartChill

HQC90

INITIALIZING

VERSION 1.00

The screen at left is displayed when the chiller is first turned on.

OVER TEMPERATURE

If CAUTION HI AIR 150°F displays, turn the chiller off, open the door and allow the excessively high temperature and humidity to evacuate the chamber. Then restart the chiller and resume the chill cycle.

If air temperature increases to 160°F, the unit will shut down and service must be called.

– 8 –

Page 8
Image 8
Hobart ML-124066, ML-124068, HQC90, HQCF45, ML-124067 manual Operation, CONTROLS Fig, Start-Up, Over Temperature