Hobart ML-124068, HQC90, HQCF45, ML-124066, ML-124067 manual Glossary

Models: ML-124067 ML-124066 HQCF45 HQC90 ML-124068

1 32
Download 32 pages 23.37 Kb
Page 30
Image 30
GLOSSARY

GLOSSARY

 

 

Alarms

— Sets the buzzer intervals after Door is Open or when to be notified that the

 

 

Compressor needs to be Cleaned.

Buzzer

— The control’s buzzer can have its volume and tone adjusted in the System Parameters.

By Temp

Chill cycle that terminates when the probes reach the Target Temperature.

By Time

Chill cycle that terminates after a set amount of time has lapsed.

By Prod

— Chill cycle that terminates after a particular product’s specified chill parameters are

 

 

met (the parameters can be set either By Temp or By Time with specific cut-offs for

 

 

a particular product.

Chill

Chilling Cycle that may end with either Time or Temperature controlled events. (Also

 

 

see Soft Chill or Freeze).

Clock

Allows the Date and Time to be entered so the system’s clock correctly records

 

 

chilling events.

Cycle #

The system assigns a consecutive number to each Chill Cycle.

Defrost

System Controlled Defrost occurs after six hours of chilling. The defrost will not

 

 

begin during a chill cycle. The system waits until it is in Holding mode before starting

 

 

the defrost cycle. The Defrost from the Main Menu is a manual defrost that will not

 

 

run if selected and unneeded. The Defrost cycle requires about 20 minutes.

Fac Presets —

Factory Presets are system parameters that are set at the factory but can be

 

 

changed by the supervisor.

Freeze

This mode is only available on model HQCF45. It allows the product to be frozen

 

 

down to a target temperature of 0°F (–18°C). The target temperature range available

 

 

for freeze mode varies from –22°F to 28°F.

Hold Prod

— After a chill mode has been done or when selected from the Main Menu, the chiller

 

 

will act like a regular refrigerator (or freezer on model HQCF45).

Label

— A condensed Chill Cycle Report that can be printed on adhesive-backed label stock

 

 

by the optional second label printer.

Logging

The time interval at which Chill Cycle data (temperature vs. time) is logged into

 

 

memory for record purposes. This time interval can be modified in Sys Par (System

 

 

Parameters) by the supervisor. The range of settings available for this time interval

 

 

is: 5, 10, 15 or 30 minutes.

Main Menu

The two initial menus available from the controller after the chiller is turned on.

Mode

Basic chiller operating parameters are available from Sys Par in Setup mode.

 

 

Chill mode parameters allow adjustment of the target temperature, the air temperature

during chill mode, the hold mode temperature, the high alarm temperature, the low alarm temperature and the maximum chill mode target temperature.

Soft Chill mode parameters apply a modification of some of the Chill settings during the final portion of the chill cycle if Soft Chill is selected. Soft Chill provides additional protection against freezing of surfaces.

Freeze mode parameters (only available on model HQCF45) provide separate freeze settings that allow a direct hard freeze of product.

– 30 –

Page 30
Image 30
Hobart ML-124068, HQC90, HQCF45, ML-124066, ML-124067 manual Glossary