•Access the Sys Par 2 menu as shown on page 21.
SYS PAR 1 | 09:07:31 |
|
|
|
CLOCK TEMPS IN °F |
|
|
| |
PROBES | LOGGING |
|
|
|
SETUP MENU | MORE | SYS PAR 2 | 09:08:41 | |
|
| REMOTE ALARM MODE | ||
|
| ALARMS |
| BUZZER |
|
| BACK | FAC PRESETS |
MODE
MODE PARAMETERS
CHILL FREEZE
SOFT CHILL
BACK
•From Sys Par 2, select MODE.
•From Mode Parameters, select FREEZE. (BACK returns to SYS PAR 2.)
FREEZE |
|
| |
FREEZE MODE EDITOR | • Set the TARGET Temp using the ↓ or ↑ keys. | ||
↓TARGET | 0° F ↑ | Range: | |
←BACK | NEXT→ | • Select NEXT to move to the next field. | |
CANCEL | ENTER | ||
| |||
FREEZE MODE EDITOR | • Set the AIR Temp using the ↓ or ↑ keys. | ||
Range: | |||
↓AIR | |||
←BACK | NEXT→ | • Select NEXT to move to the next field. | |
CANCEL | ENTER | ||
| |||
FREEZE MODE EDITOR | (BACK returns to the previous field.) | ||
| |||
↓HOLD | • Set the HOLD Temp using the ↓ or ↑ keys. | ||
←BACK | NEXT→ | ||
Range: | |||
CANCEL | ENTER | ||
| |||
FREEZE MODE EDITOR | • Select NEXT to move to the next field. | ||
| |||
↓HIGH ALARM | 32°F↑ | • Set the HIGH ALARM Temp using the ↓ or ↑ keys. | |
←BACK | NEXT→ | Range: [1°F to 35°F]. | |
CANCEL | ENTER | ||
| |||
FREEZE MODE EDITOR | • Select NEXT to move to the next field. | ||
| |||
↓LOW ALARM | • Set the LOW ALARM Temp using the ↓ or ↑ keys. | ||
←BACK | NEXT→ | Range: | |
CANCEL | ENTER | (NEXT returns to the TARGET TEMP field.) | |
|
|
•Select ENTER to accept the displayed values and return to Mode Parameters.
(CANCEL retains the previous settings and returns to Mode Parameters.)
NOTE: Freeze Mode is only available on
model HQCF45.