Access the Sys Par 2 menu as shown on page 21.

SYS PAR 1

09:07:31

 

 

 

CLOCK TEMPS IN °F

 

 

 

PROBES

LOGGING

 

 

 

SETUP MENU

MORE

SYS PAR 2

09:08:41

 

 

REMOTE ALARM MODE

 

 

ALARMS

 

BUZZER

 

 

BACK

FAC PRESETS

MODE

MODE PARAMETERS

Manual backgroundCHILL FREEZEManual background

Manual backgroundSOFT CHILL

BACKManual background

From Sys Par 2, select MODE.

From Mode Parameters, select SOFT CHILL. (BACK returns to SYS PAR 2.)

SOFT CHILL Assures against freezing by reducing air flow at end of cycle or by increasing air temp.

SOFT CHILL EDITOR

BY

TIME

70%

BACK

NEXT

CANCEL

ENTER

SOFT CHILL EDITOR

BY

TEMP

5°F

BACK

NEXT

CANCEL

ENTER

SOFT CHILL EDITOR

2ND

TEMP

28°F

BACK

NEXT

CANCEL

ENTER

[ % ] x Chill Time = Time when reduced air flow occurs.

Range: [10% to 90% ].

Set the By Time % using the or keys.

Select NEXT to move to the next field.

[_°F ] + Target Temp = Temp when reduced air flow occurs. Range: [ 5 to 20 °F].

Set the By Temp degrees using the or keys.

Select NEXT to move to the next field.

(BACK returns to the previous field.)

[ 2nd Temp ] = Sets an alternate Air Temp during the Soft Chill cycle. Range: [ 10°F to 40°F ]. Normal Air Temp (regular chill cycle) = 10 °F.

Set the 2nd Temp degrees using the or keys. (NEXT returns to the By Time field.)

Select ENTER to keep any changes and return to Mode Parameters.

(CANCEL retains the previous settings and returns to Mode Parameters.)

– 27 –