•Access the Sys Par 2 menu as shown on page 21.
SYS PAR 1 | 09:07:31 |
|
|
|
CLOCK TEMPS IN °F |
|
|
| |
PROBES | LOGGING |
|
|
|
SETUP MENU | MORE | SYS PAR 2 | 09:08:41 | |
|
| REMOTE ALARM MODE | ||
|
| ALARMS |
| BUZZER |
|
| BACK | FAC PRESETS |
MODE
MODE PARAMETERS
CHILL FREEZE
SOFT CHILL
BACK
•From Sys Par 2, select MODE.
•From Mode Parameters, select SOFT CHILL. (BACK returns to SYS PAR 2.)
SOFT CHILL — Assures against freezing by reducing air flow at end of cycle or by increasing air temp.
SOFT CHILL EDITOR | ||
↓BY | TIME | 70%↑ |
←BACK | NEXT→ | |
CANCEL | ENTER | |
SOFT CHILL EDITOR | ||
↓BY | TEMP | 5°F↑ |
←BACK | NEXT→ | |
CANCEL | ENTER | |
SOFT CHILL EDITOR | ||
↓2ND | TEMP | 28°F↑ |
←BACK | NEXT→ | |
CANCEL | ENTER |
[ % ] x Chill Time = Time when reduced air flow occurs.
Range: [10% to 90% ].
•Set the By Time % using the ↓ or ↑ keys.
•Select NEXT to move to the next field.
[_°F ] + Target Temp = Temp when reduced air flow occurs. Range: [ 5 to 20 °F].
•Set the By Temp degrees using the ↓ or ↑ keys.
•Select NEXT to move to the next field.
(BACK returns to the previous field.)
[ 2nd Temp ] = Sets an alternate Air Temp during the Soft Chill cycle. Range: [ 10°F to 40°F ]. Normal Air Temp (regular chill cycle) = 10 °F.
•Set the 2nd Temp degrees using the ↓ or ↑ keys. (NEXT returns to the By Time field.)
•Select ENTER to keep any changes and return to Mode Parameters.
(CANCEL retains the previous settings and returns to Mode Parameters.)