3-2. Connections With A CV Welding Power Source Having Separate 115 VAC And Contactor Control Receptacles

1

2

1Constant Voltage (CV) Weld- ing Power Source

2Plug

 

Obtain matching plugs for connect-

8

ing to power source receptacles.

 

3 Workpiece

4Voltage Sensing Lead Do not connect to workpiece.

5Gun

6Wire Feeder

7115 VAC/Contactor Control Cord

8Gas Cylinder

3

4

7

5

6

151 775-C

3-3. Connections With A CC Welding Power Source Having A Contactor Control Receptacle

1

2

3

5

4

6

1Constant Current (CC) Weld- ing Power Source

25-Pin Or Two-Prong Twistlock

10

9

Plug

 

Workpiece

 

3

 

4

Voltage Sensing Lead

 

5

Gun

 

6

Wire Feeder

 

7

3-Conductor Contactor Con-

 

 

trol Cord

83-Conductor 115 VAC Cord

9Gas Cylinder

10115 VAC Plug

Obtain plug for wire feeder.

8

7

151 776-B

OM-1581 Page 11

Page 15
Image 15
Hobart OM-1581 manual Constant Voltage CV Weld- ing Power Source Plug