Hobart OM-1581 manual Adjusting Hub Tension, Overload Protection

Models: OM-1581

1 56
Download 56 pages 2.66 Kb
Page 39
Image 39

5-10. Adjusting Hub Tension

 

 

 

 

 

 

 

 

 

 

Turn On welding power source and

 

 

 

wire feeder to make this

 

 

 

adjustment.

 

 

 

 

 

 

1

Wire Speed Control

 

 

 

 

 

Adjust control to wire speed for

 

 

 

welding.

 

 

 

 

 

 

2

Jog Switch

 

 

 

 

 

2

Push up, and then release Jog

 

 

switch. Hub tension is okay if wire

 

 

 

 

3

 

unwinds freely, but wire does not

1

 

backlash when

Jog

switch

is

 

 

released.

 

 

 

 

 

 

 

 

 

 

 

 

3

Cap Screw

 

 

 

 

 

 

Turn cap screw to adjust hub ten-

 

 

 

sion. Do not overtighten. Turn Off

 

 

 

welding power source and wire

 

 

 

feeder. Close and latch door.

 

Tools Needed:

 

 

 

 

 

 

 

7/16 in

 

 

 

 

 

 

 

 

 

 

 

151 778 / Ref. 802 536 / Ref. 176 700-A

5-11. Overload Protection

3

1

Push And Turn

2

Pull Out And Replace F1

Push And Turn

Turn Off wire feeder and welding power source.

If F1 opens, the unit shuts down. To check or change F1, proceed as follows:

1Fuse Holder Cover

2Fuse F1 (See Parts List For Rating)

Insert new fuse into cover, and in- stall fuse with cover by pressing and turning cover clockwise.

3 Circuit Breaker CB1

If CB1 opens, the gun drive motor and contactor will not operate, but gas flows when trigger is pulled. The gun drive motor operates in the Jog mode with CB1 open.

Check for blocked gun liner.

Check for jammed wire, binding drive gear or misaligned drive rolls in feeder. Correct problem.

Allow cooling period and manually reset breaker. Close and latch door.

Ref. 151 779-A / Ref. 800 185-A

5-12. Water Flow Switch (Optional For Water-Cooled Models)

The water flow switch protects the gun from overheating. If coolant flow rate drops below 1 qt/min, the water flow switch opens and stops the welding wire from feeding. See Section 5-13 for remedies to this trouble.