3-7. Water-Cooled Gun Connections

4 3

5

Left Side

3

2

1

7

8

6

1 Gas Hose

Connect to Gas fitting on feeder.

2 Water Hose

Connect to Water To Gun fitting on feeder (left-hand threads).

3Wire Conduit

4Thumbscrew

5Wire Conduit Block

Loosen thumbscrew, and insert conduit through Wire opening until it bottoms against block. Tighten thumbscrew.

6 Gun Control Cable

Insert plug into Gun Control recep- tacle, and tighten threaded collar.

7 Strain Relief

Remove strain relief as shown.

8 Power/Water Cable

Route cable through strain relief and connect to Weld/Water From Gun outlet on feeder. Reinstall strain relief. Close and latch door.

Tools Needed:

5/8, 1-1/8 in

Ref. 151 778-B / 152 456-A

OM-1581 Page 14

Page 18
Image 18
Hobart OM-1581 manual Water-Cooled Gun Connections