3-6. Air-Cooled Gun Connections

6 5

7

4

3

Left Side

5

2

1 Gun Control Cable

Insert plug into Gun Control recep- tacle, and tighten threaded collar.

2 Gas Hose

Connect to Gas fitting on feeder.

3Weld Cable

4Weld Cable Terminal In Feeder

Connect gun weld cable to weld cable terminal in feeder.

5Wire Conduit

6Thumbscrew

7Wire Conduit Block

Loosen thumbscrew, and insert conduit through Wire opening until it bottoms against block. Tighten thumbscrew. Close and latch door.

3

1

Tools Needed:

5/8, 3/4 in

145 432-B / Ref. 802 536 / Ref. 151 778-B

OM-1581 Page 13

Page 17
Image 17
Hobart OM-1581 manual Air-Cooled Gun Connections