Hobart Welding Products 3025 Selecting Weld Cable Sizes, Remote 14 Receptacle RC5 Information

Models: 3025

1 64
Download 64 pages 4.52 Kb
Page 20
Image 20

4-7. Selecting Weld Cable Sizes

 

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

 

 

 

 

 

 

 

 

 

Welding

100 ft (30 m) Or Less

 

150 ft

200 ft

250 ft

300 ft

350 ft

400 ft

 

(45 m)

(60 m)

(70 m)

(90 m)

(105 m)

(120 m)

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 – 60%

60 – 100% Duty

 

 

10 – 100% Duty Cycle

 

 

 

Duty Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

 

4

3

2

1

1/0

1/0

 

 

 

 

 

 

 

 

 

 

150

3

3

 

2

1

1/0

2/0

3/0

3/0

 

 

 

 

 

 

 

 

 

 

200

3

2

 

1

1/0

2/0

3/0

4/0

4/0

 

 

 

 

 

 

 

 

 

 

250

2

1

 

1/0

2/0

3/0

4/0

2-2/0

2-2/0

 

 

 

 

 

 

 

 

 

 

300

1

1/0

 

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

 

 

 

 

 

 

 

 

 

 

350

1/0

2/0

 

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

 

 

 

 

 

 

 

 

 

 

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your

distributor for the mm2 equivalent weld cable sizes.

S-0007-E

4-8. Remote 14 Receptacle RC5 Information

NOTE

Engine runs at weld/power speed whenever a device connected to the remote 14 receptacle is running.

A

J

B

K

I

 

 

C

L N

H

D

M

G

 

E

F

802 174-E

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB11.

 

 

 

B

Contact closure to A completes 24 volts ac

 

 

contactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB12.

 

 

 

J

Contact closure to I completes 115 volts ac

 

 

contactor control circuit.

 

C

Output to remote control; 0 to +10 volts dc, +10

 

 

volts dc in MIG mode.

REMOTE

D

Remote control circuit common.

OUTPUT

E

0 to +10 volts dc input command signal from

CONTROL

 

 

remote control.

 

M

CC/CV select (CC/CV models).

A/V

F

Current feedback; +1 volt dc per 100 amperes.

 

 

AMPERAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

VOLTAGE

 

tacle volts.

GND

G

Circuit common for 24 and 115 volts ac circuits.

K

Chassis common.

 

*The remaining sockets are not used.

OM-492 Page 16

Page 20
Image 20
Hobart Welding Products 3025 manual Selecting Weld Cable Sizes, Remote 14 Receptacle RC5 Information, 100 ft 30 m Or Less