Honeywell Optiflex Summary of Connections, Trigger Data, DIP Switch Settings, S E C T I O N, Tour

Models: Optiflex

1 24
Download 24 pages 42.16 Kb
Page 19
Image 19
Summary of Connections

S E C T I O N 6

Summary of Connections

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

DETAIL A

DETAIL B

PRESS

AND HOLD BOTH Trigger Data (10 SECONDS) DIP Switch Settings

UNIT RESET

DIP

SWITCH

COMPOSITE

VIDEO

OUT

12345678

ON

+12V -GND ECP GRN ECP YEL

Voltage N.C.

DETAIL A

CAMERA INPUTS

(DETAIL C)

TRIGGER 1

TRIGGER 2

TRIGGER 3

TRIGGER 4

TRIGGER 5

TRIGGER 6

TRIGGER 7

TRIGGER 8

GND

DETAIL B

10baseT

ETHERNET

3

1

5

6

4

2

DETAIL C

optiflex-SOC-V3

 

Trigger Data

 

 

 

 

 

 

 

 

 

DIP Switch Settings

 

 

 

 

 

 

 

 

 

 

 

NTSC Output Configuration (DIP Switch 1 – 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

Voltage

 

 

Dip Switch

 

Cam-1

Cam-2

Cam-3

Cam-4

Cam-5

Cam-6

 

Guard

Reserved

 

 

 

Trigger

 

 

 

 

 

View

 

View

 

View

 

View

View

 

View

 

Tour

 

 

 

 

(+12VDC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

OFF

 

ON

 

OFF

 

ON

 

OFF

 

ON

 

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

OFF

 

OFF

 

ON

 

ON

 

OFF

 

OFF

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

OFF

 

OFF

 

OFF

 

OFF

 

ON

 

ON

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 3

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 4

4

 

NTSC Guard Tour Mode – Camera Dwell Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dip Switch

 

 

2 sec

 

 

4 sec

 

 

8 sec

 

16 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera 6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

OFF

 

 

 

ON

 

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NTSC Advance

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

OFF

 

 

OFF

 

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Cameras

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NTSC Guard Tour Mode – Camera Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dip Switch

 

 

Use All Six Cameras for

 

Use the First Four

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Guard Tour

 

Cameras for Guard Tour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

OFF

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-1

Page 19
Image 19
Honeywell Optiflex setup guide Summary of Connections, Trigger Data, DIP Switch Settings, S E C T I O N, Voltage, Tour