7. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 8

Water supply inlet is 1/2" female pipe thread (FPT). A strainer should be installed with the clean-out plug down. Locate the strainer in the water supply line, next to the ice dispenser with the arrow on the strainer in the direction of the water flow.

Note: a) A Part Code 311166A01 strainer is an optional extra.

b)On water-cooled models, a 1/2" FPT is provided for the Condenser Water Inlet.

A water supply line shut-off valve and drain valve should be installed.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, use a pressure reducing valve.

Two drain outlets are 3/4" female pipe thread (FPT).

Note: On the water-cooled model, a 3/8" - 18 FPT (3/8” diameter, 18 threads/inch) is provided for the Condenser Drain Outlet.

The drains must have 1/4" fall per foot on horizontal runs to get a good flow.

Keep more than a 2" air gap between drain pipe ends or hose ends and a floor drain.

A plumbing permit and services of a licensed plumber may be required in some areas.

A back flow preventer may be required in some areas.

Only cold drinking water will be used for this icemaker.