7. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 8
•Water supply inlet is 1/2" female pipe thread (FPT). A strainer should be installed with the
Note: a) A Part Code 311166A01 strainer is an optional extra.
b)On
•A water supply line
•Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, use a pressure reducing valve.
•Two drain outlets are 3/4" female pipe thread (FPT).
Note: On the
•The drains must have 1/4" fall per foot on horizontal runs to get a good flow.
•Keep more than a 2" air gap between drain pipe ends or hose ends and a floor drain.
•A plumbing permit and services of a licensed plumber may be required in some areas.
•A back flow preventer may be required in some areas.
•Only cold drinking water will be used for this icemaker.