c. Make sure the male fitting and female coupling are properly aligned, then start the connection by hand to ensure that it is not cross threaded.

d. Place a backup wrench on the back of the female coupling, then tighten the connection with a wrench until it is tight. At this point, the nut has covered most of the threads on the male fitting. CAUTION! Failure to use a backup wrench may result in damage to the line set and possible refrigerant leaks.

e. Mark a reference line on the female coupling and the remote condenser unit or icemaker panel. Using a backup wrench on the back of the female coupling, tighten the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 8.

Remote Condenser Unit

Icemaker

Male Fitting

Female Coupling

3/8" OD Discharge Line (Insulated)

1/4" OD Liquid Line (Insulated)

Service Loop

Fig. 6

 

Male Fitting

 

 

Brush

 

Threads

Diaphragm

Apply POE Oil to

 

Entire Male Fitting

 

 

 

O-Ring

 

POLYOL

ESTER

(POE) OIL

DO NOT USE

THREAD SEALANT

THREAD

SEALANT

Fig. 7

Reference Line

Wrench

After Tight, Tighten an Additional 1/6 Turn

1/6 Turn

Backup

Wrench

Fig. 8

Backup Wrench Wrench

20

Page 20
Image 20
Hoshizaki FD-1001MRH(-C), FD-1001MLH(-C), FD-1001MAH(-C), FD-1001MWH(-C) instruction manual Polyol Ester POE OIL