5. Electrical Connection

WARNING

1.Electrical connection must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment.

2.THE REMOTE CONDENSER UNIT MUST BE GROUNDED. Install a proper ground wire from the icemaker to the remote condenser unit. Use wire of an appropriate gage and outdoor rating. Failure to properly ground the unit could result in death or serious injury.

3.The remote condenser unit leads must be connected to the fan motor junction box leads on the icemaker. Use wire of an appropriate gage and outdoor rating.

4.Do not connect the leads to an external power source. Do not connect the icemaker's fan motor junction box leads together. Do not allow the leads to contact the junction box walls.

5.To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.

6.On remote air-cooled model, the icemaker should have power for a minimum of 4 hours prior to startup to prevent compressor damage.

Usually an electrical permit and services of a licensed electrician are required.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

1)Remove the louver panel. See Fig. 9.

2)Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on the icemaker.

3)Install a ground wire from the icemaker to the remote condenser unit. Use wire of an appropriate gage and outdoor rating.

4)Connect the fan motor leads in the junction box of the remote condenser unit to the fan motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate gage and outdoor rating.

5)Replace the junction box covers and the louver panel in their correct positions.

Remote Condenser Unit

Screws

Junction Box

Cover

Louver Panel

Power Supply

Icemaker

 

Junction Box Cover

Fan Motor Junction

 

Box Cover

 

Screw

Fig. 9

 

21

 