2. Water-Cooled Condenser

a) Connection to an Open Drain System

Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.

A condenser water supply line shut-off valve and drain valve should be installed.

Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.

In some areas, a back flow preventer may be required in the cooling water circuit.

FD-1001MWH(-C)

Condenser

Condenser Drain

Connection

Outlet 3/8" FPT

 

to a Potable

Icemaker/Condenser

Water Supply

Water Supply Line

 

Shut-Off Valve

 

Condenser Water

 

Supply Inlet

 

1/2" FPT

 

Icemaker/Condenser

 

Water Supply Line

 

Drain Valve

To convert to top water supply, install the optional Top Water Supply Kit (HS-2123).

Icemaker Water

Supply Inlet

1/2" FPT

Icemaker Icemaker

Drain Outlet

3/4" FPT

Separate piping to approved drain. Leave a 2-inch (5-cm) vertical air gap between the end of each pipe and the drain.

2-inch (5-cm) air gap

Bin Drain Outlet 3/4" FPT

Storage Bin

Drain Floor

Fig. 15

28