2. Water-Cooled Condenser
a) Connection to an Open Drain System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
•A condenser water supply line
•Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.
•In some areas, a back flow preventer may be required in the cooling water circuit.
FD-1001MWH(-C)
Condenser | Condenser Drain | |
Connection | Outlet 3/8" FPT | |
| ||
to a Potable | Icemaker/Condenser | |
Water Supply | ||
Water Supply Line | ||
| ||
| Condenser Water | |
| Supply Inlet | |
| 1/2" FPT | |
| Icemaker/Condenser | |
| Water Supply Line | |
| Drain Valve |
To convert to top water supply, install the optional Top Water Supply Kit
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker Icemaker
Drain Outlet
3/4" FPT
Separate piping to approved drain. Leave a
Bin Drain Outlet 3/4" FPT
Storage Bin
Drain Floor
Fig. 15