J. Startup

WARNING

1.All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage.

2.If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.

3.At startup, confirm that all internal and external connections are free of leaks.

4.On remote air-cooled model, the icemaker should have power for a minimum of 4 hours prior to startup to prevent compressor damage.

1)Open the water supply line shut-off valve(s).

2)Remove the front panel.

3)Move the control switch on the control box to the "ICE" position, then move the power switch to the "ON" position.

4)Replace the front panel in its correct position.

5)Turn on the power supply to start the automatic icemaking process.

6)Once the unit starts to produce ice, allow it to run for another 30 minutes.

7)Turn off the power supply, then remove the front panel.

8)Move the control switch to the "DRAIN" position, then replace the front panel in its correct position. Turn on the power supply and allow the water system to drain for 5 minutes.

9)Turn off the power supply, then remove the front panel.

10)Move the control switch to the "ICE" position, then replace the front panel in its correct position.

11)Pour warm water into the dispenser unit/storage bin and melt any remaining ice. Clean the dispenser unit/storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.

12)Turn on the power supply to start the automatic icemaking process.

13)Confirm bin control operation. See "II.K. Bin Control Check."