3. Infrared Sensor Shutdown Delay
This is the delay between the infrared sensor detecting ice and the start of the shutdown sequence. The infrared sensor shutdown delay is
a) Standard Storage Bin:
When installed on a standard storage bin, any shutdown delay setting is acceptable.
b) Dispenser Unit:
For typical dispenser unit applications, a
Note: When the shutdown sequence begins, the compressor
WARNING
Increasing the shutdown delay allows a higher level of ice in the dispensing unit/storage bin before shutdown. This could lead to icemaker movement or ice overflow.
S1 Dip Switch | Shutdown Delay | |||
|
|
| ||
NO. 1 | NO. 2 | NO. 3 | ||
| ||||
|
|
|
| |
OFF | OFF | OFF | 0 seconds | |
ON | OFF | OFF | 100 seconds (1.6 minutes) | |
OFF | ON | OFF | 1100 seconds (18.3 minutes) | |
OFF | OFF | ON | 1650 seconds (27.5 minutes) | |
ON | ON | OFF | 2200 seconds (36.7 minutes) | |
|
|
|
| |
OFF | ON | ON | 0 seconds | |
ON | ON | ON | 0 Seconds |