Hoshizaki FD-1001MRH(-C), FD-1001MLH(-C), FD-1001MAH(-C), FD-1001MWH(-C) Sanitizing Procedure Final

Models: FD-1001MLH(-C) FD-1001MAH(-C) FD-1001MWH(-C) FD-1001MRH(-C)

1 44
Download 44 pages 33.43 Kb
Page 40
Image 40

14)Turn on the power supply and allow the solution to drain for 5 minutes.

15)Turn off the power supply.

5.Sanitizing Procedure - Final

1)Mix a new batch of the sanitizing solution.

2)Make sure the power supply is off and the water supply line shut-off valve is closed. Remove the front and top panels, then move the power switch to the "OFF" position.

3)Remove the strap connecting the spout to the chute assembly, then remove the spout.

4)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are full and the solution starts to overflow into the drain pan.

5)Replace the spout and strap in their correct positions.

6)Allow the icemaker to sit for about 10 minutes before operation.

7)Move the control switch to the "ICE" position, then move the power switch to the "ON" position. Replace the panels in their correct positions, then turn on the power supply. Make ice using the solution until the icemaker stops making ice.

8)Turn off the power supply, then remove the front panel. Move the control switch to the "DRAIN" position, then replace the front panel in its correct position.

9)Turn on the power supply and allow the solution to drain for 5 minutes.

10)Turn off the power supply, then remove the front panel. Move the control switch to the "ICE" position, then replace the front panel in its correct position.

11)Open the water supply line shut-off valve, then turn on the power supply to supply water to the reservoir.

12)After the gear motor starts, turn off the power supply. Remove the front panel, then move the control switch to the "DRAIN" position. Replace the front panel in its correct position.

13)Turn on the power supply and allow the water system to drain for 5 minutes.

14)Turn off the power supply, then remove the front panel. Move the control switch to the "ICE" position, then replace the front panel in its correct position.

15)Turn on the power supply to start the automatic icemaking process. Allow the icemaker to run for about 30 minutes, then turn off the power supply.

16)Pour warm water into the dispenser unit/storage bin and melt any remaining ice. Clean the dispenser unit/storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.

17)Turn on the power supply to start the automatic icemaking process.

40

Page 40
Image 40
Hoshizaki FD-1001MRH(-C), FD-1001MLH(-C), FD-1001MAH(-C), FD-1001MWH(-C) instruction manual Sanitizing Procedure Final