2. LED Lights and Audible Alarm Safeties

The "POWER OK" LED indicates proper control voltage and will remain on unless a control voltage problem occurs. For further details, see "II.B. Sequence of Operation."

Sequence Step

LED

Energized

 

 

Components

Min.

Max.

 

 

Fill Cycle

WTRIN

WV

-

-

Ice Purge Cycle

GM

GM, EH

5 min.

5 min.

Freeze Cycle (with refill)

GM, COMP,

GM, EH, PDS, Comp,

-

*On until UF/S closes.

 

WTRIN* (refill),

FMR,

 

Alarm sounds after

 

 

WV* (refill)

 

90 sec.

1-in-1 Drain Cycle

FLUSH (Drain)

DV

2 sec.

2 sec.

(S1 dip switch 4 off)

GM, COMP

Comp, GM, EH, PDS,

 

 

 

(only if IS not

FMR (only if IS not

 

 

 

satisfied)

satisfied)

 

 

 

 

 

 

 

1-in-12 Drain Cycle

FLUSH (Drain)

DV

10 min.

10 min.

(S1 dip switch 4 on)

 

 

 

 

The built-in alarm safeties shut down the unit.

No. of Beeps

Type of Alarm

Reset Options

(every 5 sec.)

 

 

1

Low Water Safety

Automatic reset once water supply is restored

 

UF/S open > 90 seconds after WV energized.

and UF/S closes.

2

Control Switch

Automatic reset once the control switch is

 

In "DRAIN" position longer than 15 minutes.

moved to the "ICE" position.

3

High-Pressure Switch: N/A on this model.

See "III.B.2. SRC-10H" for high-pressure

4

High-Pressure Switch: N/A on this model.

switch operation.

5

Freeze Timer

Manual reset. Turn power off and on again.

 

WV off > 30 minutes since last WV activation.

 

6

Low Voltage

"POWER OK" LED turns off if voltage

 

(92VAC±5% or less)

protection operates.

7

High Voltage

The control voltage safeties automatically

 

(147VAC±5% or more)

reset when voltage is corrected.

8

Gear Motor

Manual reset. Turn power off and on again.

 

GMPR contacts fail to close.

 

9

Infrared Sensor (S1 dip switch 7)

Manual reset. Turn power off and on again.

 

MBC actuator paddle engaged.

 

Legend: DV–drain valve; EH–evaporator heater; FMR–fan motorremote; GM–gear motor; IS–infrared sensor bin control; MBC–mechanical backup bin control; PDS-pumpdown solenoid valve; WV–inlet water valve