9)Refill Cycle/Low Water Safety Cycle "GM", "COMP", and "WTRIN" LEDs are on. As ice is produced, the water level in the reservoir drops. UF/S opens. Nothing happens at this time. When LF/S opens, WV energizes, 90-second low water safety timer (fill timer) starts. GMR (X2 on CB), GM, GMPR, EH, PDS, MC, Comp, and FMR continue. When LF/S closes, nothing happens at this time. When UF/S closes, WV de-energizes, 90-second low water safety timer (fill timer) terminates, and 30minute freeze timer starts.

If UF/S remains open 90 seconds after WV energizes (LF/S opens) (fill timer exceeded), a 90-second shutdown cycle starts. CB X1 relay de-energizes, de- energizing PDS. Refrigeration circuit low-side pressure drops to 9 PSIG, opening CLPS. CLPS opens de-energizing MC, Comp, and FMR. CB signals a 1-beep alarm every 5 seconds. 90-second purge timer starts. GMR (X2 on CB), GM, GMPR, and EH continue. 90-second purge timer terminates, GMR (X2 on CB), GM, GMPR, and EH deenergizes. WV and 1-beep alarm continue until UF/S closes.

Diagnosis – Check that "WTRIN" LED is on. If not, check that LF/S is open. See "IV.E. Float Switch Check and Cleaning." If LF/S is open and "WTRIN" LED is off, CB is bad and must be replaced. If "WTRIN" LED is on, check that the reservoir fills. If not, check for water supply line shutoff valve closed, clogged water filters, and clogged WV screen. Next, check 24VAC to WV from CB K2 connector pin #8 white/brown (W/BR) wire to a light blue (LBU) neutral wire. Check for continuity through WV solenoid. If open, replace WV. If WV is energized and refill exceeds 90-second low water safety timer (fill timer) with no water in the reservoir, check for DV leaking. If reservoir is full and overflowing check that UF/S closes. If not, check UF/S continuity, red (R) wire to black (BK) wire.

Clean or replace if necessary. See "IV.E. Float Switch Check and Cleaning."

Note: Each time UF/S closes, 30-minute freeze timer starts. The 30-minute freeze timer resets when UF/S closes again. If UF/S does not close again within 30 minutes, CB shuts down the unit and sounds a 5-beep alarm every 5 seconds. See

"II.C.2. LED Lights and Audible Alarm Safeties."

10)Shutdown – See "IV.D. Bin Control Check."

Legend: CB–control board; CLPS–control low-pressure switch; Comp–compressor; DV–drain valve; EH–evaporator heater; FMR–fan motorremote; GM–gear motor; GMPR–gear motor protect relay; GMR–gear motor relay; HM–headmaster; HPS–highpressure switch; IS–infrared sensor; LF/S–lower float switch; MC–magnetic contactor; MBC–mechanical backup bin control; PDS–pump-down solenoid valve; SLPS–safety low-pressure switch; UF/S–upper float switch; WV–inlet water valve