No Ice Production - Possible Cause
| Ice Purge Cycle Continued | |
3. Gear Motor Protect Relay | a) Open windings. | |
|
| |
| b) Contacts stuck open. | |
|
| |
| Freeze Cycle | |
|
| |
1. Gear Motor Protect Relay | a) Open. | |
2. Control Board | a) No power to | |
|
| |
| b) X1 relay defective. | |
|
| |
3. | a) Open coil. | |
|
| |
| b) Sticking. | |
4. Magnetic Contactor | a) Open coil. | |
|
| |
| b) Contacts sticking. | |
|
| |
5. Control | a) Refrigerant pressure too low. | |
|
| |
| b) Out of adjustment or defective. | |
6. Safety | a) Refrigerant pressure too low. | |
(manual reset) |
| |
b) Defective. | ||
| ||
|
| |
7. | a) Dirty condenser. | |
|
| |
| b) Ambient temperature too warm. | |
| c) Fan motor not operating. | |
| d) Refrigerant overcharged. | |
|
| |
| e) Bad contacts. | |
|
| |
| f) Refrigerant lines or components restricted. | |
|
| |
8. Condensing Unit Fan Motor | a) Magnetic contactor contacts bad or coil winding open. | |
| b) Motor winding open. | |
|
| |
| c) Bearing worn out or locked rotor. | |
|
| |
| d) Capacitor defective. | |
|
| |
9. Compressor | a) Magnetic contactor contacts bad or coil winding open. | |
| b) Motor winding open. | |
|
| |
| c) Start capacitor or run capacitor defective. | |
|
| |
| d) Start relay contacts bad or coil winding open. | |
|
| |
10. Evaporator | a) Dirty. | |
| b) Damaged or defective. | |
|
| |
11. Expansion Valve (TXV) | a) Bulb loose. | |
|
| |
| b) Operating erratically. | |
|
| |
12. Refrigerant Charge | a) Low. | |
13. Drain Valve | a) Dirty, leaking by. | |
|
| |
| b) Defective coil. | |
|
| |
| c) Defective control board. | |
|
| |
14. Water System | a) Water leaks. | |
| Refill | |
|
| |
1. Float Switch | a) Dirty/sticking. | |
|
| |
| b) Defective. | |
|
| |
2. Inlet Water Valve | a) Clogged or defective. | |
3. Water Supply | a) Off. |