3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact Hoshizaki Technical Support at
a)Default Dip Switch Settings
The S1 dip switch settings are
S1 Dip Switch No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
ON | OFF | OFF | OFF | OFF | OFF | ON | ON | OFF | OFF |
Normally off (factory use)
Mechanical Backup Bin Control Shutdown Delay Bin Control Selector
Continuous Dispensing Timer
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Infrared Sensor Shutdown Delay
b)Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)
Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice
(yellow LED flashing or steady) and the start of the shutdown sequence. For dispenser unit applications, the ice level at shutoff may need to be adjusted depending on the dispenser agitation or dispense method. Increasing the shutdown delay setting allows for a higher level of ice in the bin before the icemaker shuts down. For a typical dispenser unit application, a 100‑second shutdown delay is recommended. When used with a standard Hoshizaki storage bin, any shutdown delay setting is acceptable.
WARNING
Increasing the shutdown delay allows a higher level of ice in the dispensing unit/storage bin before shutdown. This could lead to icemaker movement or ice overflow.
S1 Dip Switch Setting | Infrared Sensor Shutdown Delay | |||
|
|
| ||
No. 1 | No. 2 | No. 3 | ||
| ||||
|
|
|
| |
OFF | OFF | OFF | 0 Seconds | |
|
|
|
| |
ON | OFF | OFF | 100 Seconds (1.6 minutes) (Factory Default) | |
OFF | ON | OFF | 1100 Seconds (18.3 minutes) | |
|
|
|
| |
OFF | OFF | ON | 1650 Seconds (27.5 minutes) | |
|
|
|
| |
ON | ON | OFF | 2200 Seconds (36.7 minutes) | |
|
|
|
| |
OFF | ON | ON | 0 Seconds | |
|
|
|
| |
ON | ON | ON | 0 Seconds |
19