Chapter 6 Fault Code Information and Maintenance

 

Fault

Fault Descriptions

 

 

Corrective Actions

 

 

Name

 

 

 

 

 

 

 

 

 

 

 

CANopen Heartbeat Time out

 

Connect to CAN bus again and reset CAN bus

 

 

 

 

 

 

 

 

(Only for VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

CANopen SYNC Time out

 

Check if CANopen synchronous message is

 

 

 

abnormal

 

 

(Only for VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CANopen SDO Time out

 

Check if command channels are full

 

 

 

 

 

 

 

 

(Only for VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

 

CANopen SDO buffer

 

1.

Too short time between commands, please

 

 

 

 

check SDO message sent from the master

 

 

overflow(Only for

 

 

 

 

 

2.

Reset CAN bus

 

 

VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAN bus off(Only for

 

1.

Check if it connects to terminal resistor

 

 

 

2.

Check if the signal is abnormal

 

 

VFDxxxExxC)

 

 

 

 

3.

Check if the master is connected

 

 

 

 

 

 

CAN Boot up fault(Only for

 

1.

Check if the master is connected

 

 

 

2.

Reset CAN bus

 

 

VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error communication protocol

 

Check if the communication protocol is correct

 

 

 

 

 

 

 

 

of CANopen (Only for

 

 

 

 

 

 

VFDxxxExxC)

 

 

 

 

 

 

 

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

6-5

Page 226
Image 226
Delta Electronics VFD-E manual Fault Fault Descriptions Corrective Actions Name