Chapter 4 Parameters

Parameter

Explanation

Settings

Factory

Customer

Setting

09.03

Time-out Detection

0.1 ~ 120.0 seconds

0.0

 

0.0: Disable

 

 

 

 

 

 

 

 

 

 

 

 

0: 7,N,2 (Modbus, ASCII)

 

 

 

 

1: 7,E,1 (Modbus, ASCII)

 

 

09.04

Communication

2: 7,O,1 (Modbus, ASCII)

0

 

 

 

Protocol

3: 8,N,2 (Modbus, RTU)

 

 

 

 

 

 

 

 

 

 

4: 8,E,1 (Modbus, RTU)

 

 

 

 

5: 8,O,1 (Modbus, RTU)

 

 

 

 

6: 8,N,1 (Modbus, RTU)

 

 

 

 

7: 8,E,2 (Modbus, RTU)

 

 

 

 

8: 8,O,2 (Modbus, RTU)

 

 

 

 

9: 7,N,1 (Modbus, ASCII)

 

 

 

 

10: 7,E,2 (Modbus, ASCII)

 

 

 

 

11: 7,O,2 (Modbus, ASCII)

 

 

 

 

 

 

 

09.05

Reserved

 

 

 

 

 

 

 

 

09.06

Reserved

 

 

 

 

 

 

 

 

09.07

Response Delay

0 ~ 200 (unit: 2ms)

1

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Baud rate 4800 bps

 

 

 

Transmission Speed

1: Baud rate 9600 bps

 

 

09.08

2: Baud rate 19200 bps

2

 

 

for USB Card

3: Baud rate 38400 bps

 

 

 

 

 

 

 

 

4: Baud rate 57600 bps

 

 

 

 

 

 

 

 

 

0: 7,N,2 for ASCII

 

 

 

Communication

1: 7,E,1 for ASCII

 

 

 

2: 7,O,1 for ASCII

 

 

09.09

Protocol for USB

1

 

3: 8,N,2 for RTU

 

 

Card

 

 

 

4: 8,E,1 for RTU

 

 

 

 

 

 

 

 

5: 8,O,1 for RTU

 

 

 

 

 

 

 

4-24

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11