Chapter 4 Parameters

 

Group 12: Analog Input/Output Parameters for Extension Card

 

 

 

 

 

 

 

Parameter

Explanation

Settings

Factory

Customer

Setting

 

 

0: Disabled

 

 

 

 

1: Source of the 1st frequency

 

 

12.00

AI1 Function

2: Source of the 2nd frequency

0

 

 

 

Selection

3: PID Set Point (PID enable)

 

 

 

 

 

 

 

 

 

 

4: Positive PID feedback

 

 

 

 

5: Negative PID feedback

 

 

 

 

 

 

 

12.01

AI1 Analog Signal

0: ACI2 analog current (0.0 ~ 20.0mA)

1

 

 

 

Mode

1: AVI3 analog voltage (0.0 ~ 10.0V)

 

 

 

 

 

 

 

 

 

 

 

 

 

12.02

Min. AVI3 Input

0.0 to 10.0V

0.0

 

Voltage

 

 

 

 

 

 

 

 

 

 

12.03

Min. AVI3 Scale

0.0 to 100.0%

0.0

 

Percentage

 

 

 

 

 

 

 

 

 

 

12.04

Max. AVI3 Input

0.0 to 10.0V

10.0

 

Voltage

 

 

 

 

 

 

 

 

 

 

12.05

Max. AVI3 Scale

0.0 to 100.0%

100.0

 

Percentage

 

 

 

 

 

 

 

 

 

 

12.06

Min. ACI2 Input

0.0 to 20.0mA

4.0

 

Current

 

 

 

 

 

 

 

 

 

 

12.07

Min. ACI2 Scale

0.0 to 100.0%

0.0

 

Percentage

 

 

 

 

 

 

 

 

 

 

12.08

Max. ACI2 Input

0.0 to 20.0mA

20.0

 

Current

 

 

 

 

 

 

 

 

 

 

12.09

Max. ACI2 Scale

0.0 to 100.0%

100.0

 

Percentage

 

 

 

 

 

 

 

 

 

 

 

 

0: Disabled

 

 

 

 

1: Source of the 1st frequency

 

 

12.10

AI2 Function

2: Source of the 2nd frequency

0

 

Selection

3: PID Set Point (PID enable)

 

 

 

 

 

 

4: Positive PID feedback

 

 

 

 

5: Negative PID feedback

 

 

 

 

 

 

 

12.11

AI2 Analog Signal

0: ACI3 analog current (0.0 ~ 20.0mA)

1

 

 

 

Mode

1: AVI4 analog voltage (0.0 ~ 10.0V)

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

4-29

Page 82
Image 82
Delta Electronics VFD-E manual Parameters