Appendix D How to Use PLC Function

 

 

 

 

 

 

 

 

 

 

 

 

 

Ladder diagram:

 

Command code: Operation:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LDF

 

X0

 

Start X0 falling-edge detection

 

 

 

 

X0

X1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

AND

 

X1

Series connection A contact of X1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

Y1

Drive Y1 coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANDP

 

 

 

 

Rising-edge series connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operand

X0~X17

 

Y0~Y17

 

 

M0~M159

 

T0~15

 

C0~C7

 

D0~D29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

--

 

 

9

 

 

9

 

9

 

 

9

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations:

ANDP command is used in the series connection of the contacts’ rising-edge detection.

Program Example:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ladder diagram:

Command code: Operation:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LD

 

X0

 

 

Load A contact of X0

 

 

 

 

 

X0

X1

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANDP

 

X1

 

 

X1 rising-edge detection in series connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

Y1

 

 

Drive Y1 coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

 

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANDF

 

 

 

 

 

Falling-edge series connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operand

 

X0~X17

 

Y0~Y17

 

M0~M159

 

T0~15

 

C0~C7

D0~D29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

9

 

9

 

9

 

9

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations:

ANDF command is used in the series connection of the contacts’ falling-edge detection.

Program Example: Ladder diagram:

X0 X1

 

Command code:

Operation:

 

LD

X0

Load A contact of X0

Y1

 

 

 

ANDF

X1

X1 falling-edge detection in series

 

 

 

connection

 

 

 

 

OUT Y1

Drive Y1 coil

D-42

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Page 325
Image 325