09.06Reserved

09.07

Response Delay Time

Unit: 2ms

 

 

 

 

 

Settings

0 ~ 200 (400msec)

Factory Setting: 1

 

 

 

 

This parameter is the response delay time after AC drive receives communication command as shown in the following. 1 unit = 2 msec.

RS485 BUS

PC or PLC command

Handling time of AC drive Max.: 6msec

Response Message of AC Drive

Response Delay Time

Pr.09.07

09.08Transmission Speed for USB Card

Factory Setting: 2

Settings

0

Baud rate 4800 bps

 

1

Baud rate 9600 bps

 

2

Baud rate 19200 bps

 

3

Baud rate 38400 bps

 

4

Baud rate 57600 bps

 

 

 

This parameter is used to set the transmission speed for USB card.

09.09Communication Protocol for USB Card

Factory Setting: 1

Settings

0

Modbus ASCII mode, protocol <7,N,2>

 

1

Modbus ASCII mode, protocol <7,E,1>

 

2

Modbus ASCII mode, protocol <7,O,1>

 

3

Modbus RTU mode, protocol <8,N,2>

 

4

Modbus RTU mode, protocol <8,E,1>

 

5

Modbus RTU mode, protocol <8,O,1>

 

6

Modbus RTU mode, protocol <8,N,1>

 

 

 

 

7

Modbus RTU mode, protocol <8,E,2>

 

8

Modbus RTU mode, protocol <8,O,2>

 

9

Modbus ASCII mode, protocol <7,N,1>

 

10

Modbus ASCII mode, protocol <7,E,2>

 

11

Modbus ASCII mode, protocol <7,O,2>

 

 

 