Chapter 4 Parameters

 

 

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 440.0

 

 

 

 

01.34

 

Mid-Point Frequency (Fmid) (Motor 2)

Unit: 0.01

 

 

Settings

0.10 to 600.0Hz

 

Factory Setting: 1.50

 

 

 

 

 

01.35

Mid-Point Voltage (Vmid) (Motor 2)

Unit: 0.1

 

 

Settings

115V/230V series

0.1 to 255.0V

Factory Setting: 10.0

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 20.0

 

 

 

 

 

01.36

Minimum Output Frequency (Fmin) (Motor 2)

Unit: 0.01

 

 

Settings

0.10 to 600.0Hz

 

Factory Setting: 1.50

 

 

 

 

 

01.37

Minimum Output Voltage (Vmin) (Motor 2)

Unit: 0.1

 

 

Settings

115V/230V series 0.1 to 255.0V

Factory Setting: 10.0

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 20.0

 

 

 

01.38

Maximum Voltage Frequency (Fbase) (Motor 3)

Unit: 0.01

 

 

Settings

0.10 to 600.0Hz

Factory Setting: 60.00

 

 

01.39

 

Maximum Output Voltage (Vmax) (Motor 3)

Unit: 0.1

 

 

Settings

115V/230V series

0.1 to 255.0V

Factory Setting: 220.0

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 440.0

 

 

01.40

 

Mid-Point Frequency (Fmid) (Motor 3)

Unit: 0.01

 

 

Settings

0.10 to 600.0Hz

 

Factory Setting: 1.50

 

 

01.41

 

Mid-Point Voltage (Vmid) (Motor 3)

Unit: 0.1

 

 

Settings

115V/230V series

0.1 to 255.0V

Factory Setting: 10.0

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 20.0

 

 

01.42

 

Minimum Output Frequency (Fmin) (Motor 3)

Unit: 0.01

 

 

Settings

0.10 to 600.0Hz

 

Factory Setting: 1.50

 

 

01.43

 

Minimum Output Voltage (Vmin) (Motor 3)

Unit: 0.1

 

 

Settings

115V/230V series 0.1 to 255.0V

Factory Setting: 10.0

 

 

 

460V series

0.1 to 510.0V

Factory Setting: 20.0

 

 

 

 

 

 

The V/f curve of motor 0 to motor 3 can be selected by setting the multi-function input terminals MI3~MI6 (Pr.04.05 to Pr.04.08) to 27 and 28.

Group 2: Operation Method Parameters

02.00Source of First Master Frequency Command

Factory Setting: 1

02.09Source of Second Master Frequency Command

Factory Setting: 0

Settings 0 Digital keypad UP/DOWN keys or Multi-function Inputs UP/DOWN. Last used frequency saved. (Digital keypad is optional)

4-50

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Page 103
Image 103
Delta Electronics VFD-E manual 01.34, 01.38, 01.39, 01.40, 01.41, 01.42, 01.43