Delta Electronics VFD-E manual Revision June 2008, 04EE, SW--PW V1.11/CTL 139

Models: VFD-E

1 363
Download 363 pages 22.75 Kb
Page 192
Image 192

 

 

Chapter 4 Parameters

Settings

Function

Description

9

Desired Frequency

Active when the desired frequency (Pr.03.02) is attained.

Attained

 

 

 

 

 

10

Terminal Count Value

Active when the counter reaches Terminal Count Value.

Attained

 

 

 

 

 

11

Preliminary Count Value

Active when the counter reaches Preliminary Count Value.

Attained

 

 

 

 

 

12

Over Voltage Stall

Active when the Over Voltage Stall function operating

supervision

 

 

13

Over Current Stall

Active when the Over Current Stall function operating

supervision

 

 

 

Heat Sink Overheat

When heatsink overheats, it will signal to prevent OH turn

14

off the drive. When it is higher than 85oC (185oF), it will be

Warning

 

ON.

 

 

 

 

 

15

Over Voltage supervision

Active when the DC-BUS voltage exceeds level

 

 

 

16

PID supervision

Active when the PID function is operating

 

 

 

17

Forward command

Active when the direction command is FWD

 

 

 

18

Reverse command

Active when the direction command is REV

 

 

 

19

Zero Speed Output

Active unless there is an output frequency present at

Signal

terminals U/T1, V/T2, and W/T3.

 

 

 

 

 

Communication Warning

 

20

(FbE,Cexx, AoL2, AUE,

Active when there is a Communication Warning

 

SAvE)

 

 

 

 

21

Brake Control (Desired

Active when output frequency Pr.03.14. Deactivated when

Frequency Attained)

output frequency Pr.03.15 after STOP command.

 

 

 

 

11.06Multi-function Input Terminal (MI7)

11.07Multi-function Input Terminal (MI8)

11.08Multi-function Input Terminal (MI9)

11.09Multi-function Input Terminal (MI10)

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11