Appendix D How to Use PLC Function

Special D

Function

Read(R)/ Write(W)

D1025

The present value of the high-speed counter C235 (low byte)

R

 

 

 

D1026

The present value of the high-speed counter C235 (high byte)

R

 

 

 

D1027

Frequency command of the PID control

R

 

 

 

D1028

The value of AVI (analog voltage input) 0-10V corresponds to 0-

R

1023

 

 

 

 

 

 

The value of ACI (analog current input) 4-20mA corresponds to 0-

 

D1029

1023 or the value of AVI2 (analog voltage input) 0-10V

R

 

corresponds to 0-1023

 

 

 

 

D1030

The value of V.R digital keypad 0-10V corresponds to 0-1023

R

 

 

 

D1031-

Reserved

--

D1035

 

 

 

 

 

D1036

PLC error code

R

 

 

 

D1037-

Reserved

--

D1039

 

 

 

 

 

D1040

Analog output value

R/W

 

 

 

D1041-

Reserved

--

D1042

 

 

 

 

 

D1043

User defined (when Pr.00.04 is set to 2, the register data will be

R/W

displayed as C xxx)

 

 

 

 

 

D1044

High-speed counter mode

R/W

 

 

 

D.4.10 Communication Addresses for Devices (only for PLC2 mode)

Device

Range

Type

X

00–17 (octal)

Bit

 

 

 

Y

00–17 (octal)

Bit

 

 

 

T

00-15

Bit/word

 

 

 

M

000-159

Bit

 

 

 

M

1000-1031

Bit

 

 

 

C

0-7

Bit/word

 

 

 

D

00-63

Word

 

 

 

D

1000-1044

Word

 

 

 

Address (Hex)

0400-040F

0500-050F

0600-060F

0800-089F 0BE8-0C07 0E00-0E07 1000-101D 13E8-1414

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

D-27

Page 310
Image 310