Chapter 4 Parameters

If temperature exceeds the motor PTC overheat warning level (Pr.07.15), the drive will act

according to Pr.07.17 and display . If the temperature decreases below the result (Pr.07.15 minus Pr.07.16), the warning display will disappear.

07.13

Input Debouncing Time of the PTC Protection

Unit: 2

 

Settings

0~9999 (is 0-19998ms)

Factory Setting: 100

 

 

 

 

This parameter is to delay the signals on PTC analog input terminals. 1 unit is 2 msec, 2 units

are 4 msec, etc.

 

 

07.18

Motor Rated Current (Motor 1)

Unit: 1

 

Settings

30% FLA to 120% FLA

Factory Setting: FLA

 

 

 

07.19

Motor No-load Current (Motor 1)

Unit: 1

 

 

 

 

 

Settings

0% FLA to 90% FLA

Factory Setting: 0.4*FLA

 

 

 

07.20

Torque Compensation (Motor 1)

Unit: 0.1

 

Settings

0.0 to 10.0

Factory Setting: 0.0

 

 

 

07.21

Slip Compensation (Used without PG) (Motor 1)

Unit: 0.01

 

Settings

0.00 to 10.00

Factory Setting: 0.00

 

 

 

07.22

Motor Line-to-line Resistance R1 (Motor 1)

Unit: 1

 

Settings

0 to 65535 mΩ

Factory Setting: 0

 

 

 

07.23

Motor Rated Slip (Motor 1)

Unit: 0.01

 

Settings

0.00 to 20.00Hz

Factory Setting: 3.00

 

 

 

07.24

Motor Pole Number (Motor 1)

Unit: 1

 

Settings

2 to 10

Factory Setting: 4

 

 

 

07.25

Motor Rated Current (Motor 2)

Unit: 1

 

Settings

30% FLA to 120% FLA

Factory Setting: FLA

 

 

 

07.26

Motor No-load Current (Motor 2)

Unit: 1

 

 

 

 

 

Settings

0% FLA to 90% FLA

Factory Setting: 0.4*FLA

 

 

 

07.27

Torque Compensation (Motor 2)

Unit: 0.1

 

Settings

0.0 to 10.0

Factory Setting: 0.0

07.28

Slip Compensation (Used without PG) (Motor 2)

Unit: 0.01

 

Settings

0.00 to 10.00

Factory Setting: 0.00

 

 

 

07.29

Motor Line-to-line Resistance R1 (Motor 2)

Unit: 1

 

Settings

0 to 65535 mΩ

Factory Setting: 0

 

 

 

07.30

Motor Rated Slip (Motor 2)

Unit: 0.01

 

Settings

0.00 to 20.00Hz

Factory Setting: 3.00

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11