Chapter 4 Parameters

 

Parameter

Explanation

Settings

 

Factory

Customer

 

Setting

 

 

3: Fan ON when preliminary heatsink

 

 

 

 

temperature attained

 

 

 

 

 

 

 

 

 

 

 

Read only

 

 

 

 

 

Bit0=1:RLY used by PLC

 

 

 

 

 

Bit1=1:MO1 used by PLC

 

 

 

 

The Digital Output

Bit2=1:MO2/RA2 used by PLC

 

 

 

03.09

Used by PLC

Bit3=1:MO3/RA3 used by PLC

 

##

 

(NOT for VFD*E*C

 

 

 

 

 

 

 

 

models)

Bit4=1:MO4/RA4 used by PLC

 

 

 

 

 

Bit5=1:MO5/RA5 used by PLC

 

 

 

 

 

Bit6=1:MO6/RA6 used by PLC

 

 

 

 

 

Bit7=1:MO7/RA7 used by PLC

 

 

 

 

 

 

 

 

 

 

The Analog Output

Read only

 

 

 

 

Bit0=1:AFM used by PLC

 

 

 

03.10

Used by PLC

 

##

 

(NOT for VFD*E*C

Bit1=1: AO1 used by PLC

 

 

 

 

 

 

 

models)

Bit2=1: AO2 used by PLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03.11

Brake Release

0.00 to 20.00Hz

 

0.00

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

03.12

Brake Engage

0.00 to 20.00Hz

 

0.00

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read only

 

 

 

 

 

Bit0: RLY Status

 

 

 

 

 

Bit1: MO1 Status

 

 

 

03.13

Display the Status of

Bit2: MO2/RA2 Status

 

 

 

Multi-function

Bit3: MO3/RA3 Status

 

##

 

 

Output Terminals

Bit4: MO4/RA4 Status

 

 

 

 

 

 

 

 

 

 

Bit5: MO5/RA5 Status

 

 

 

 

 

Bit6: MO6/RA6 Status

 

 

 

 

 

Bit7: MO7/RA7 Status

 

 

 

 

 

 

 

 

 

03.14

Desired Frequency

0.00 to 600.0Hz

 

0.00

 

2 Attained

 

 

 

 

 

 

 

 

 

 

 

 

 

Group 4 Input Function Parameters

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

4-11

Page 64
Image 64
Delta Electronics VFD-E manual Group 4 Input Function Parameters