Delta Electronics VFD-E manual Devices Functions, „ The Function of Input/output Contacts

Models: VFD-E

1 363
Download 363 pages 22.75 Kb
Page 303
Image 303

Appendix D How to Use PLC Function

 

 

 

 

Items

Specifications

 

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When timer attains, the

 

 

 

T

Present value of timer

T0~T15, 16 points

 

contact of timer will be

 

 

 

 

 

 

 

 

 

On.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When timer attains, the

 

 

 

C

Present value of counter

C0~C7, 8-bit counter, 8 points

contact of timer will be

 

data

 

 

 

 

 

 

 

On.

 

 

 

 

 

 

 

 

 

 

WORD

 

 

 

 

 

 

 

 

 

 

 

 

For latched

D0~D9, 10 points

 

Total is

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

 

It can be memory area

 

 

 

D

For general

D10~D29, 20 points

 

 

 

 

 

75

 

Register

 

 

register

 

 

 

points

for storing data.

 

 

 

 

For special

D1000~D1044, 45

 

 

 

 

 

 

points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Constant

K

Decimal

 

K-32,768 ~ K32,767 (16-bit operation)

 

 

 

 

 

 

 

 

 

H

Hexadecimal

 

H0000 ~ HFFFF (16-bit operation)

 

 

 

 

 

 

 

 

 

 

 

Communication port (for read/write

RS485 (slave)

 

 

program)

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog input/output

 

Built-in 2 analog inputs and 1 analog output

 

 

Function extension module (optional)

Digital input/output card (A/D, D/A card)

 

 

 

 

 

 

 

 

 

 

D.4.2 Devices Functions

„The Function of Input/output Contacts

The function of input contact X: input contact X reads input signal and enter PLC by connecting with input equipment. It is unlimited usage times for A contact or B contact of each input contact X in program. The On/Off of input contact X can be changed with the On/Off of input equipment but can’t be changed by using peripheral equipment (WPLSoft).

„The Function of Output Contact Y

The mission of output contact Y is to drive the load that connects to output contact Y by sending On/Off signal. There are two kinds of output contact: one is relay and the other is transistor. It is unlimited usage times for A or B contact of each output contact Y in program. But there is number for output coil Y and it is recommended to use one time in program. Otherwise, the output result will be decided by the circuit of last output Y with PLC program scan method.

D-20

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Page 303