Appendix A Specifications

 

 

 

 

General Specifications

 

 

 

 

AC drive operating, frequency attained, zero speed, Base Block, fault

 

Multi-function Output Indication

indication, overheat alarm, emergency stop and status selections of input

 

 

 

terminals

 

 

Analog Output Signal

Output frequency/current

 

 

 

 

 

 

 

Alarm Output Contact

Contact will be On when drive malfunctions (1 Form C/change-over contact

 

 

and 1 open collector output) for standard type)

 

 

 

 

 

 

 

Built-in PLC(NOT for CANopen models), AVR, accel/decel S-Curve, over-

 

 

 

voltage/over-current stall prevention, 5 fault records, reverse inhibition,

 

 

 

momentary power loss restart, DC brake, auto torque/slip compensation,

 

 

 

auto tuning, adjustable carrier frequency, output frequency limits, parameter

 

 

Operation Functions

lock/reset, vector control, PID control, external counter, MODBUS

 

 

 

communication, abnormal reset, abnormal re-start, power-saving, fan control,

 

 

 

sleep/wake frequency, 1st/2nd frequency source selections, 1st/2nd

 

 

 

frequency source combination, NPN/PNP selection, parameters for motor 0

 

 

 

to motor 3, DEB and OOB (Out Of Balance Detection)(for washing machine)

 

 

 

Protection Functions

Over voltage, over current, under voltage, external fault, overload, ground

 

 

fault, overheating, electronic thermal, IGBT short circuit, PTC

 

 

 

 

 

 

6-key, 7-segment LED with 4-digit, 5 status LEDs, master frequency, output

 

Display Keypad (optional)

frequency, output current, custom units, parameter values for setup and lock,

 

 

 

faults, RUN, STOP, RESET, FWD/REV, PLC

 

 

 

 

VFD002E11T/21T/23T, VFD004E11T/21T/23T/43T,

 

 

 

VFD007E21T/23T/43T, VFD015E23T/43T, VFD007E11A, VFD015E21A,

 

 

Built-in Brake Chopper

VFD022E21A/23A/43A, VFD037E23A/43A VFD007E11C, VFD015E21C,

 

 

VFD022E21C/23C/43C, VFD037E23C/43C, VFD055E23A/43A,

 

 

 

 

 

 

VFD075E23A/43A, VFD110E43A, VFD055E23C/43C, VFD075E23C/43C,

 

 

 

VFD110E43C

 

 

 

Built-in EMI Filter

For 230V 1-phase and 460V 3-phase models.

 

 

 

 

 

 

 

Enclosure Rating

IP20

Conditions

 

 

 

 

 

Pollution Degree

2

 

 

 

 

 

 

Installation Location

Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust

 

 

 

 

Environmental

 

Ambient Temperature

-10oC to 50oC (40oC for side-by-side mounting) Non-Condensing and not

 

 

frozen

 

 

 

 

 

 

 

 

Storage/ Transportation

-20 oC to 60 oC

 

 

Temperature

 

 

 

 

Ambient Humidity

Below 90% RH (non-condensing)

 

 

 

Vibration

9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz

Approvals

 

 

 

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

A-3

Page 236
Image 236
Delta Electronics VFD-E manual Conditions