Setting

 

 

10: Current exceeds 2 times rated current

 

 

 

 

during decel.(ocd)

 

 

 

 

11: Current exceeds 2 times rated current

 

 

 

 

during steady state operation (ocn)

 

 

 

 

12: Ground fault (GFF)

 

 

 

 

13: Reserved

 

 

 

 

14: Phase-Loss (PHL)

 

 

 

 

15: Reserved

 

 

 

 

16: Auto Acel/Decel failure (CFA)

 

 

06.10

Third Most Recent

17: SW/Password protection (codE)

 

 

 

Fault Record

18: Power Board CPU WRITE failure (cF1.0)

 

 

 

 

 

 

 

 

19: Power Board CPU READ failure (cF2.0)

 

 

 

 

20: CC, OC Hardware protection failure

 

 

 

 

(HPF1)

 

 

 

 

 

 

 

06.11

Fourth Most Recent

21: OV Hardware protection failure (HPF2)

 

 

 

 

 

 

Fault Record

22: GFF Hardware protection failure (HPF3)

 

 

 

 

 

 

 

 

23: OC Hardware protection failure (HPF4)

 

 

 

 

24: U-phase error (cF3.0)

 

 

 

 

25: V-phase error (cF3.1)

 

 

06.12

Fifth Most Recent

 

 

 

 

 

Fault Record

26: W-phase error (cF3.2)

 

 

 

 

 

 

 

 

 

27:DCBUS error (cF3.3)

28:IGBT Overheat (cF3.4)

29:Power Board Overheat (cF3.5)

30:Control Board CPU WRITE failure (cF1.1)

31:Control Board CPU WRITE failure (cF2.1)

32:ACI signal error (AErr)

33:Reserved

34:Motor PTC overheat protection (PtC1) 35-39: Reserved

40:Communication time-out error of control board and power board (CP10)