Delta Electronics VFD-E manual One

Models: VFD-E

1 363
Download 363 pages 22.75 Kb
Page 230
Image 230

 

 

Chapter 6 Fault Code Information and Maintenance

 

Terminals and wiring of main circuit

 

 

 

 

 

 

 

Maintenance

 

Check Items

Methods and Criterion

 

Period

 

 

 

 

 

 

Daily

Half

One

 

 

 

 

 

 

Year

Year

 

 

 

 

 

 

 

If the wiring shows change of

 

 

 

 

 

color change or deformation due

Visual inspection

 

{

 

 

to overheat

 

 

 

 

 

 

 

 

 

 

 

If the insulation of wiring is

 

 

 

 

 

damaged or the color has

Visual inspection

 

{

 

 

changed

 

 

 

 

 

 

 

 

 

 

 

If there is any damage

Visual inspection

 

{

 

 

 

 

 

 

 

DC capacity of main circuit

 

 

 

 

 

 

 

Maintenance

 

Check Items

Methods and Criterion

 

Period

 

 

 

 

 

 

Daily

Half

One

 

 

 

 

 

 

Year

Year

 

 

 

 

 

 

 

If there is any leakage of liquid,

 

 

 

 

 

change of color, cracks or

Visual inspection

{

 

 

 

deformation

 

 

 

 

 

 

 

 

 

 

 

Measure static capacity when

Static capacity initial value X 0.85

 

{

 

 

required

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistor of main circuit

 

 

 

 

 

 

 

Maintenance

 

Check Items

Methods and Criterion

 

Period

 

 

 

 

 

 

Daily

Half

One

 

 

 

 

 

 

Year

Year

 

 

 

 

 

 

 

If there is any peculiar smell or

 

 

 

 

 

insulator cracks due to

Visual inspection, smell

 

{

 

 

overheating

 

 

 

 

 

 

 

 

 

 

 

 

Visual inspection or measure with

 

 

 

 

If there is any disconnection

multimeter after removing wiring

 

{

 

 

between +/B1 ~ -

 

 

 

 

Resistor value should be within ± 10%

 

 

 

 

 

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11