Appendix D How to Use PLC Function

 

Program Example:

 

 

 

 

 

 

 

 

Ladder diagram:

 

Command code:

 

Operation:

 

 

 

 

 

X0

X1

 

LDI

X0

 

Load contact B of X0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

AND

X1

 

Connect to contact A of X1 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

Y1

 

Drive Y1 coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

Latch (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operand

X0~X17

 

Y0~Y17

M0~M159

 

T0~15

C0~C7

D0~D29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

--

 

 

9

 

9

--

--

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations:

When the SET command is driven, its specific device is set to be “ON,” which will keep “ON” whether the SET command is still driven. You can use the RST command to set the device to “OFF”.

Program Example:

 

 

 

 

 

 

 

 

 

 

 

 

Ladder diagram:

 

 

 

 

Command code:

Operation:

 

 

 

 

X0 Y0

 

 

 

 

LD

X0

Load contact A of X0

 

 

 

 

 

 

 

 

 

SET

 

Y1

 

 

ANI

Y0

Connect to contact B of Y0 in series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET

Y1

Y1 latch (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mnemonic

 

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RST

 

 

 

 

 

Clear the contacts or the registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operand

X0~X17

 

 

Y0~Y17

 

M0~M159

T0~15

 

C0~C7

D0~D29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

--

 

 

9

 

9

9

 

9

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

D-37