Chapter 4 Parameters

Settings

Function

Description

 

13

 

Over Current Stall

Active when the Over Current Stall function operating

 

supervision

 

 

 

 

 

 

 

14

 

Heat Sink Overheat

When heatsink overheats, it will signal to prevent OH turn off

 

Warning

 

the drive. When it is higher than 85oC (185oF), it will be ON.

 

 

 

 

 

 

 

 

15

 

Over Voltage supervision

Active when the DC-BUS voltage exceeds level

 

 

 

 

 

 

16

 

PID supervision

Active when the PID feedback signal is abnormal (Refer to

 

Pr.10.12 and Pr.13.)

 

 

 

 

 

 

17

 

Forward command

Active when the direction command is FWD

 

 

 

 

 

18

 

Reverse command

Active when the direction command is REV

 

 

 

 

 

 

19

 

Zero Speed Output

Active when the drive is standby or stop

 

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication Warning

 

 

 

20

 

(FbE,Cexx, AoL2, AUE,

Active when there is a Communication Warning

 

 

SAvE)

 

 

 

 

 

 

 

 

 

21

 

Brake Control (Desired

Active when output frequency Pr.03.11. Deactivated when

 

Frequency Attained)

output frequency Pr.03.12 after STOP command.

 

 

 

 

 

 

 

 

22

 

Drive Ready

 

Active when the drive is on and no abnormality detected.

 

 

 

 

 

 

23

 

Desired Frequency 2

Active when the desired frequency 1(Pr.03.14) is attained.

 

Attained

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03.02

 

Desired Frequency 1 Attained

 

Unit: 0.01

 

03.14

Desired Frequency 2 Attained

Unit: 0.01

 

 

Settings

0.00 to 600.0 Hz

Factory Setting: 0.00

If a multi-function output terminal is set to function as Desired Frequency Attained (Pr.03.00 to Pr.03.01=09), then the output will be activated when the programmed frequency is attained.

4-62