Appendix D How to Use PLC Function

Ladder Diagram Structure

Explanation

Command

Equipment

 

 

MPS

 

 

Multiple output

MRD

none

 

 

MPP

 

 

Output command of coil drive

OUT

Y, M, S

 

 

 

Please refer to

 

Basic command, Application

Application

basic command

 

command

command

and application

 

 

 

command

 

Inverse logic

INV

none

D.3.3 The Edition of PLC Ladder Diagram

The program edited method is from left power line to right power line. (the right power line will be omitted during the edited of WPLSoft.) After editing a row, go to editing the next row. The maximum contacts in a row are 11 contacts. If you need more than 11 contacts, you could have the new row and start with continuous line to continue more input devices. The continuous number will be produced automatically and the same input point can be used repeatedly. The drawing is shown as follows.

X0 X1 X2 X3 X4 X5 X6 X7 X10 C0 C1

00000 X11 X12 X13

00000

 

 

 

 

 

 

 

Y0

 

 

 

 

 

 

Row Number

The operation of ladder diagram is to scan from left upper corner to right lower corner. The output handling, including the operation frame of coil and application command, at the most right side in ladder diagram.

Take the following diagram for example; we analyze the process step by step. The number at the right corner is the explanation order.

X0 X1

M0

X3 M1

Y1

X4

 

 

 

 

 

 

 

 

 

 

 

 

T0 M3

Y1

TMR T0 K10

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

D-11

Page 294
Image 294