Appendix A Specifications

 

 

 

 

Voltage Class

 

 

 

460V Class

 

 

 

 

 

 

 

Model Number VFD-XXXE

004

007

015

022

 

037

055

075

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Applicable Motor Output (kW)

0.4

0.75

1.5

2.2

 

3.7

5.5

7.5

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Applicable Motor Output (hp)

0.5

1.0

2.0

3.0

 

5.0

7.5

10

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating

 

Rated Output Capacity (kVA)

1.2

2.0

3.3

4.4

 

6.8

9.9

13.7

18.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Output Current (A)

1.5

2.5

4.2

5.5

 

8.2

13

18

24

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Output Voltage (V)

 

 

3-Phase Proportional to Input Voltage

 

 

 

 

 

 

Output Frequency (Hz)

 

 

 

0.1~600 Hz

 

 

 

 

 

 

 

 

Carrier Frequency (kHz)

 

 

 

 

1-15

 

 

 

 

 

 

 

 

Rated Input Current (A)

 

 

 

3-phase

 

 

 

 

 

 

Rating

 

1.9

3.2

4.3

7.1

 

11.2

14

19

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Voltage/Frequency

 

 

3-phase, 380-480V, 50/60Hz

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Tolerance

 

 

 

± 10%(342~528V)

 

 

 

 

 

 

 

 

Frequency Tolerance

 

 

 

± 5%(47~63Hz)

 

 

 

 

 

 

Cooling

Method

Natural Cooling

 

 

 

Fan Cooling

 

 

 

 

 

Weight (kg)

1.2

1.2

1.2

1.9

 

1.9

4.2

4.2

4.2

 

Control Characteristics

Operating Characteristics

 

 

General Specifications

Control System

SPWM(Sinusoidal Pulse Width Modulation) control (V/f or sensorless vector

control)

 

 

Frequency Setting Resolution

0.01Hz

Output Frequency Resolution

0.01Hz

Torque Characteristics

Including the auto-torque/auto-slip compensation; starting torque can be

150% at 3.0Hz

 

 

Overload Endurance

150% of rated current for 1 minute

Skip Frequency

Three zones, setting range 0.1-600Hz

Accel/Decel Time

0.1 to 600 seconds (2 Independent settings for Accel/Decel time)

Stall Prevention Level

Setting 20 to 250% of rated current

DC Brake

 

Operation frequency 0.1-600.0Hz, output 0-100% rated current

 

Start time 0-60 seconds, stop time 0-60 seconds

 

 

Regenerated Brake Torque

Approx. 20% (up to 125% possible with optional brake resistor or externally

mounted brake unit, 1-15hp (0.75-11kW) models have brake chopper built-in)

 

 

V/f Pattern

 

4-point adjustable V/f pattern

Frequency

Keypad

Setting by

 

Potentiometer-5kΩ/0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-

Setting

External Signal

 

function Inputs 3 to 9 (15 steps, Jog, up/down)

 

 

Operation

Keypad

Set by RUN and STOP

Setting

External Signal

2 wires/3 wires (MI1, MI2, MI3), JOG operation, RS-485 serial interface

Signal

(MODBUS), programmable logic controller

 

 

Multi-step selection 0 to 15, Jog, accel/decel inhibit, 2 accel/decel switches,

Multi-function Input Signal

counter, external Base Block, ACI/AVI selections, driver reset, UP/DOWN

 

 

key settings, NPN/PNP input selection

 

 

 

A-2

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11