Appendix E CANopen Function

Index

Sub

Definition

 

 

Factory

R/W

Size

Unit

NOTE

 

 

Setting

 

 

 

 

 

 

 

 

 

 

3

Inhibit time

 

 

 

 

RW

U16

100us

It is set to be

 

 

 

 

0

multiple of 10.

 

4

Reserved

 

 

 

3

RW

U8

 

 

 

5

Event timer

 

 

 

0

RW

U16

1ms

 

 

0

Number

 

 

 

2

RW

U8

 

 

0x1A00

1

1.Mapped Object

 

0x60410010

RW

U32

 

 

2

2.Mapped Object

 

0x60430010

RW

U32

 

 

 

3

3.Mapped Object

 

 

 

0

RW

U32

 

 

 

4

4.Mapped Object

 

 

 

0

RW

U32

 

 

 

0

Number

 

 

 

0

RW

U8

 

 

0x1A01

1

1.Mapped Object

 

 

 

0

RW

U32

 

 

2

2.Mapped Object

 

 

 

0

RW

U32

 

 

 

3

3.Mapped Object

 

 

 

0

RW

U32

 

 

 

4

4.Mapped Object

 

 

 

0

RW

U32

 

 

 

 

 

 

 

 

 

 

 

 

Index

Sub

Definition

Factory

RW

Size

Unit

Map

 

NOTE

Setting

 

 

 

 

 

 

 

 

 

 

0x6007

0

Abort connection

2

 

RW

S16

 

Yes

0: No action

 

 

2: Disable Voltage

option code

 

 

 

 

 

 

 

 

 

 

3: Quick stop

 

 

 

 

 

 

 

 

 

0x603F

0

Error code

0

 

RO

U16

 

Yes

 

 

 

 

 

 

 

 

 

 

 

bit 0 ~ 3: switch status

 

 

 

 

 

 

 

 

 

bit 4: rfg enable

0x6040

0

Control word

0

 

RW

U16

 

Yes

bit 5: rfg unlock

 

 

 

 

 

 

 

 

 

bit 6: rfg use ref

 

 

 

 

 

 

 

 

 

bit 7: Fault reset

 

 

 

 

 

 

 

 

 

Bit0 Ready to switch on

 

 

 

 

 

 

 

 

 

Bit1 Switched on

 

 

 

 

 

 

 

 

 

Bit2 Operation enabled

 

 

 

 

 

 

 

 

 

Bit3 Fault

 

 

 

 

 

 

 

 

 

Bit4 Voltage enabled

 

 

 

 

 

 

 

 

 

Bit5 Quick stop

0x6041

0

Status word

0

 

RO

U16

 

Yes

Bit6 Switch on disabled

 

 

Bit7 Warning

 

 

 

 

 

 

 

 

 

Bit8

 

 

 

 

 

 

 

 

 

 

Bit9 Remote

 

 

 

 

 

 

 

 

 

Bit10 Target reached

 

 

 

 

 

 

 

 

 

Bit11 Internal limit active

 

 

 

 

 

 

 

 

 

Bit12 - 13

 

 

 

 

 

 

 

 

 

Bit14 - 15

0x6042

0

vl target velocity

0

 

RW

S16

rpm

Yes

 

 

0x6043

0

vl velocity

0

 

RO

S16

rpm

Yes

 

 

demand

 

 

 

 

 

 

 

 

 

 

 

 

 

0x604F

0

vl ramp function

10000

RW

U32

1ms

Yes

If Pr.01.19 is set to 0.1, the

unit must be 100ms and

time

 

 

 

 

 

 

 

 

can’t be set to 0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If Pr.01.19 is set to 0.1, the

0x6050

0

vl slow down time

10000

RW

U32

1ms

Yes

unit must be 100ms and

 

 

 

 

 

 

 

 

 

can’t be set to 0.

 

 

 

 

 

 

 

 

 

If Pr.01.19 is set to 0.1, the

0x6051

0

vl quick stop time

1000

RW

U32

1ms

Yes

unit must be 100ms and

 

 

 

 

 

 

 

 

 

can’t be set to 0.

E-12

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Page 361
Image 361
Delta Electronics VFD-E manual Index Sub Definition Factory Size Unit Setting