Delta Electronics VFD-E manual Command message Address 01H Function 08H Data address 00H

Models: VFD-E

1 363
Download 363 pages 22.75 Kb
Page 173
Image 173

Chapter 4 Parameters

RTU mode:

Command message:

Address

01H

 

 

Function

08H

 

 

Data address

00H

 

00H

 

 

 

Data content

17H

 

70H

 

 

 

CRC CHK Low

EEH

 

 

CRC CHK High

1FH

 

 

Response message:

Address

01H

 

 

Function

08H

 

 

Data address

00H

 

00H

 

 

 

Data content

17H

 

70H

 

 

 

CRC CHK Low

EEH

 

 

CRC CHK High

1FH

 

 

(4)10H: write multiple registers (write multiple data to registers) Example: Set the multi-step speed,

Pr.05.00=50.00 (1388H), Pr.05.01=40.00 (0FA0H). AC drive address is 01H.

ASCII Mode:

Command message:

STX

‘:’

Address 1

‘0’

Address 0

‘1’

Function 1

‘1’

Function 0

‘0’

Starting data

‘0’

‘5’

address

‘0’

 

‘0’

Number of data

‘0’

‘0’

(count by word)

‘0’

 

‘2’

Number of data

‘0’

(count by byte)

‘4’

 

‘1’

The first data

‘3’

content

‘8’

 

‘8’

The second data

‘0’

‘F’

content

‘A’

 

‘0’

LRC Check

‘9’

‘A’

 

END

CR

LF

 

Response message:

STX

‘:’

Address 1

‘0’

Address 0

‘1’

Function 1

‘1’

Function 0

‘0’

Starting data

‘0’

‘5’

address

‘0’

 

‘0’

Number of data

‘0’

‘0’

(count by word)

‘0’

 

‘2’

LRC Check

‘E’

‘8’

 

END

CR

LF

 

4-120

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Page 173
Image 173
Delta Electronics VFD-E manual Command message Address 01H Function 08H Data address 00H