Delta Electronics VFD-E manual Keypad Display is Abnormal, Phase Loss PHL

Models: VFD-E

1 363
Download 363 pages 22.75 Kb
Page 216
Image 216

5.7 Keypad Display is Abnormal

Abnormal display or no display

Yes

Cycle power to AC motor drive

Display normal?

No

 

Yes

AC motor drive works normally

Chapter 5 Troubleshooting

Fix connector and eliminate noise

No

Check if all connectors are connect correctly and no noise is present

Yes

AC motor drive has malfunction.

Please contact DELTA.

5.8 Phase Loss (PHL)

 

Phase loss

 

 

 

 

 

 

No

 

 

 

 

Check wiring at R, S and T terminals

 

 

 

Yes

 

 

 

 

 

 

 

 

 

Correct wiring

Check if the screws of terminals are tightened

No

 

Tighten all screws

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

Check if the input voltage of R, S, T is unbalanced

No

Yes

Please check the wiring and power system for abnormal power

Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA.

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

5-5

Page 216
Image 216
Delta Electronics VFD-E manual Keypad Display is Abnormal, Phase Loss PHL