c) Drain Frequency Control (S1 dip switch 4)
This unit is factory set for optimum performance with the
S1 Dip Switch Setting | Drain Timer Interval | Drain Valve Open | |
No. 4 | |||
|
| ||
|
|
| |
OFF | 1 Hour | 2 Seconds | |
|
|
| |
ON | 11 Hours 45 Minutes | 10 Minutes |
d) Continuous Dispensing Timer (S1 dip switch 5 & 6)
DCM models only. The dispense mode switch on DCMs must be in the "CONTINUOUS" position for this setting to apply. The factory setting allows ice to be dispensed continuously as long as the dispense solenoid is activated.
S1 Dip Switch Setting | Dispense Time | ||
No. 5 | No. 6 | ||
| |||
|
|
| |
OFF | OFF | No Limit | |
|
|
| |
ON | OFF | 20 Seconds | |
OFF | ON | 60 Seconds | |
|
|
| |
ON | ON | No Limit | |
|
|
|
e)Bin Control Selector (S1 dip switch 7)
This unit is factory set for infrared sensor bin control operation. No adjustment is required. When used on a standard ice storage bin, the mechanical bin control may be used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the factory default position (S1 dip switch 7 in the on position), the gear motor delay after the upper float switch closes is 30 seconds. When the mechanical bin control is used (S1 dip switch 7 in the off position), the gear motor delay after the upper float switch closes is
5 seconds. WARNING! Do not place S1 dip switch 7 in the off position on dispenser unit applications.
S1 Dip Switch |
|
| |
Setting | Bin Control Application | Gear Motor Delay | |
No. 7 |
|
| |
|
|
| |
OFF | Mechanical Bin Control (Standard Ice Storage Bins Only) | 5 seconds | |
ON | Infrared Sensor with | 30 seconds | |
Mechanical Bin Control Backup | |||
|
| ||
|
|
|
20