6.
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 | 1339 | 607 |
| 1297 | 589 |
| 1203 | 546 |
|
|
|
| 80/27 | 1307 | 593 |
| 1243 | 564 |
| 1127 | 511 |
lbs./day |
| kg./day |
| 90/32 | 1297 | 589 |
| 1197 | 543 |
| 1088 | 494 |
|
| 100/38 | 1266 | 574 |
| 1171 | 531 |
| 988 | 448 | ||
|
| |||||||||||
APPROXIMATE ELECTRIC | 70/21 |
| 2090 |
|
| 2105 |
|
| 2160 | |||
CONSUMPTION | 80/27 |
| 2101 |
|
| 2124 |
|
| 2199 | |||
|
|
|
| 90/32 |
| 2105 |
|
| 2140 |
|
| 2208 |
watts |
|
|
| 100/38 |
| 2128 |
|
| 2156 |
|
| 2270 |
APPROXIMATE WATER | 70/21 | 463 | 1.75 |
| 384 | 1.45 |
| 338 | 1.28 | |||
CONSUMPTION PER 24 HR. | 80/27 | 403 | 1.52 |
| 279 | 1.06 |
| 269 | 1.02 | |||
|
| m3/day | 90/32 | 384 | 1.45 |
| 192 | 0.72 |
| 165 | 0.63 | |
gal./day |
| 100/38 | 291 | 1.10 |
| 185 | 0.70 |
| 141 | 0.53 | ||
FREEZING CYCLE TIME | 70/21 |
| 31 |
|
| 32 |
|
| 35 | |||
|
|
|
| 80/27 |
| 32 |
|
| 34 |
|
| 37 |
|
|
|
| 90/32 |
| 32 |
|
| 35 |
|
| 39 |
min. |
|
|
| 100/38 |
| 33 |
|
| 36 |
|
| 42 |
HARVEST CYCLE TIME | 70/21 |
| 3.9 |
|
| 3.4 |
|
| 3.2 | |||
|
|
|
| 80/27 |
| 3.5 |
|
| 2.8 |
|
| 2.8 |
|
|
|
| 90/32 |
| 3.4 |
|
| 2.2 |
|
| 2.1 |
min. |
|
|
| 100/38 |
| 2.9 |
|
| 2.2 |
|
| 2.1 |
HEAD PRESSURE | 70/21 | 214 | 15.0 |
| 228 | 16.0 |
| 252 | 17.7 | |||
|
|
|
| 80/27 | 224 | 15.8 |
| 246 | 17.3 |
| 273 | 19.2 |
|
|
|
| 90/32 | 228 | 16.0 |
| 261 | 18.4 |
| 287 | 20.2 |
PSIG | kg/cm2G | 100/38 | 234 | 16.5 |
| 267 | 18.8 |
| 311 | 21.9 | ||
SUCTION PRESSURE | 70/21 | 50 | 3.5 |
| 51 | 3.6 |
| 54 | 3.8 | |||
|
|
|
| 80/27 | 50 | 3.5 |
| 51 | 3.6 |
| 56 | 3.9 |
|
|
|
| 90/32 | 51 | 3.6 |
| 52 | 3.7 |
| 56 | 3.9 |
PSIG | kg/cm2G | 100/38 | 52 | 3.7 |
| 53 | 3.7 |
| 60 | 4.2 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 17,500 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2,400 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
CONDENSER VOLUME | 133 | CU. IN |
Note:
1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
48