6. KM-1301SRH3 (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

1339

607

 

1297

589

 

1203

546

 

 

 

 

80/27

1307

593

 

1243

564

 

1127

511

lbs./day

 

kg./day

 

90/32

1297

589

 

1197

543

 

1088

494

 

 

100/38

1266

574

 

1171

531

 

988

448

 

 

APPROXIMATE ELECTRIC

70/21

 

2090

 

 

2105

 

 

2160

CONSUMPTION

80/27

 

2101

 

 

2124

 

 

2199

 

 

 

 

90/32

 

2105

 

 

2140

 

 

2208

watts

 

 

 

100/38

 

2128

 

 

2156

 

 

2270

APPROXIMATE WATER

70/21

463

1.75

 

384

1.45

 

338

1.28

CONSUMPTION PER 24 HR.

80/27

403

1.52

 

279

1.06

 

269

1.02

 

 

m3/day

90/32

384

1.45

 

192

0.72

 

165

0.63

gal./day

 

100/38

291

1.10

 

185

0.70

 

141

0.53

FREEZING CYCLE TIME

70/21

 

31

 

 

32

 

 

35

 

 

 

 

80/27

 

32

 

 

34

 

 

37

 

 

 

 

90/32

 

32

 

 

35

 

 

39

min.

 

 

 

100/38

 

33

 

 

36

 

 

42

HARVEST CYCLE TIME

70/21

 

3.9

 

 

3.4

 

 

3.2

 

 

 

 

80/27

 

3.5

 

 

2.8

 

 

2.8

 

 

 

 

90/32

 

3.4

 

 

2.2

 

 

2.1

min.

 

 

 

100/38

 

2.9

 

 

2.2

 

 

2.1

HEAD PRESSURE

70/21

214

15.0

 

228

16.0

 

252

17.7

 

 

 

 

80/27

224

15.8

 

246

17.3

 

273

19.2

 

 

 

 

90/32

228

16.0

 

261

18.4

 

287

20.2

PSIG

kg/cm2G

100/38

234

16.5

 

267

18.8

 

311

21.9

SUCTION PRESSURE

70/21

50

3.5

 

51

3.6

 

54

3.8

 

 

 

 

80/27

50

3.5

 

51

3.6

 

56

3.9

 

 

 

 

90/32

51

3.6

 

52

3.7

 

56

3.9

PSIG

kg/cm2G

100/38

52

3.7

 

53

3.7

 

60

4.2

TOTAL HEAT OF REJECTION FROM CONDENSER

17,500

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,400

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

133

CU. IN (URC-14F)

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.